Regarding the indicator lamps
Lighting and blinking of the POWER indicator, the TEMP indicator, the LAMP
indicator, the
SECURITY indicator and the SHUTTER indicator have the meanings
as described in the table below. Please follow the instructions within the table.
(Continued on next page)
POWER TEMP LAMP
SECURITY
SHUTTER
Description
Lighting
In
Orange
Turned
off
Turned
off
Turned
off
Turned
off
The projector is in a standby state.
Refer to the section “Turning on/off”.
Blinking
In
Green
Turned
off
Turned
off
Turned
off
Turned
off
The projector is warming up.
Please wait.
Lighting
In
Green
Turned
off
Turned
off
Turned
off
Turned
off
The projector is in an on state.
Ordinary operations may be performed.
Blinking
In
Orange
Turned
off
Turned
off
Turned
off
Turned
off
The projector is cooling down.
Please wait.
Turned
off
Turned
off
Turned
off
Blinking
In
Red
Turned
off
The PIN Lock or (and)
TRANSITION DETECTOR is (are) on.
Refer to the description
.
Turned
off
Turned
off
Turned
off
Turned
off
Blinking
In
Yellow
The SHUTTER is closed.
Refer to the description
.
Blinking
In
Red
(discre-
tionary)
(discre-
tionary)
Turned
off
Turned
off
The projector is cooling down. A certain error has
been detected.
Please wait until the POWER indicator finishes blinking
and then perform the proper measure using the item
descriptions below.
Blinking
In
Red
or
Lighting
In
Red
Turned
off
Lighting
In
Red
Turned
off
Turned
off
The lamp does not light and there is a possibility
that interior portion has become heated.
Turn off the power and allow the projector to
cool down at least 20 minutes. After the projector has
sufficiently cooled down, confirm
the following items and then turn on the power again.
• Is there blockage of the air passage aperture?
• Is the air filter dirty?
Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy,
change the lamp referring to the section “Lamp unit”.
Blinking
In
Red
or
Lighting
In
Red
Turned
off
Blinking
In
Red
Turned
off
Turned
off
The lamp cover has not been properly fixed.
Turn off the power and allow the projector to
cool down at least 45 minutes. After the projector has
sufficiently cooled down, confirm
the attachment state of the lamp cover. After performing
any needed maintenance, turn on the power again.