10.5 Confirming the Normality of the Storage System after Removing Controller Chassis
1. Checking Normality
Perform the procedure described in "Checking Normality" (TRBL02-06-10).
2. Executing LAN Check
Perform a diagnosis of LAN Check (DIAG03-10).
When there is an error, perform Recovery Procedure for Error Parts Detected by LAN Check
(TRBL02-04-440).
3. Click [Logout] to close the window.
4. Click [Execute]-[Exit] in the SVP window to exit the window.
NOTE: At this point, the removed CTLs are displayed as selectable CTLs for Connect to.
5. Removing the Maintenance PC
Remove the Maintenance PC from the storage system referring to Attachment/Removal Procedure of
Maintenance PC (INST(IN)13-02-10).