DKC910IHitachi Proprietary
[INST(RM)03-02-60]
Rev.0.1
INST(RM)03-02-60
Figure 3-9 Removing the Drive (FBX)
(2) Installing dummy (Drive).
(a) Install the dummy (Drive) in the slot from which the Drive has been removed.
NOTE : Be sure to insert the dummy (Drive) in the free slot because it is necessary to regulate
a cooling air flow inside the Storage System.
(b) Insert it into the slot slowly so that the latch part of the dummy (Drive) comes to the lower
side.
Figure 3-10 Installing the Dummy (Drive) (FBX)
Address label
Drive
Rail
SHIELD SPRING
Stopper
Drive
FBX
Handle
Safekeeping box
FBX
Latch
Dummy (Drive)