raidcom monitor pool
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E21 8102 A shared memory for Dynamic Tiering or active
flash is not installed.
CMDRJE Executing 2E21 9000 The program product of Dynamic Tiering or active
flash is not installed.
CMDRJE Executing 2E30 6002 Start or stop of performance monitor by hand
cannot be performed because it is a pool for
Dynamic Provisioning or it is automatic execution
mode.
CMDRJE Executing 2E30 6003 The specified pool is the one for Thin Image or
Copy-on-Write Snapshot.
CMDRJE Executing 2EE7 FEEC An internal error occurred. Call Hitachi Data
Systems customer support.
Table 9-105 SSB codes returned by raidcom reallocate pool
raidcom reallocate pool
Error message
Executing/
Async
Error code
Description
SSB1 SSB2
CMDRJE Executing 2E00 6000 The value of pool ID is out of range.
CMDRJE Executing 2E10 6007 There is not enough time after collecting
performance monitor.
CMDRJE Executing 2E10 6008 Tier Reallocation cannot be started because the
state of performance monitor information is not
enabled. Start the performance monitor again.
CMDRJE Executing 2E10 6009 Reallocation cannot be started because it is
reallocating.
CMDRJE Executing 2E10 600A Reallocation cannot be stopped because it is not
reallocating.
CMDRJE Executing 2E10 6011 The operation cannot be performed because it is
being discarded pages.
CMDRJE Executing 2E10 6015 The operation cannot be performed because the
Tier is being deterred reallocation.
CMDRJE Executing 2E11 6003 The pool is not in the status of specifying the
reallocation to start or stop.
CMDRJE Executing 2E20 6000 The pool ID is not installed.
CMDRJE Executing 2E21 8101 A shared memory for Dynamic Provisioning is not
installed.
CMDRJE Executing 2E21 8102 A shared memory for Dynamic Tiering or active
flash is not installed.
Troubleshooting
9-155
Command Control Interface User and Reference Guide