28
PJ-TX100(C11H)
By the control panel By the remote control transmitter
1. Display the menu by the
“MENU” button.
2. Select the “OPTION” on the
menu.
3. Continue press the button “
rst, then press the button “
together with “INPUT”, and hold
for 3 seconds.
1. Display the menu by the
“MENU” button. (If EASY
MENU appears, choose “Go to
Advance menu” to display
ADVANCE MENU.)
2. Select the “OPTION” on the menu.
3. Press the “LIGHT” button.
Next hold the “LIGHT” button
for 3 seconds.
To display the OSD for “HIDDEN SERVICE MENU” set up.
Setup of Filter time (“ON” or “OFF”)
1. Select the “FILTER TIME” on the OSD using button “ ” .
Next press the “ ” to select “FILTER TIME MENU” by the HIDDEN SERVICE MENU.
FILTER TIME
ON
OFF
2. ON : Select the “ON” on the OSD using button “ ”.
OFF : Select the “OFF” on the OSD using button “ ”.
3. The OSD will be ended by no operation for 10 seconds or change of input signal. To end immediately, use
one of buttons except buttons “ ”, “ ”, “ ”, “ ”.
Set operating time display method (accumulated lamp time display method)
1. Select OPTION” from the Advance menu, then place the cursor on the “LAMP TIME”.
2. Press the [Reset] button once, then press [LIGHT] button of the remote control for 3 seconds or more to
display the screen shown below. (The menu will close after 10 seconds if there are no further operations.)
3. Use ” or “ ” to select the usage status number. (The usage status is as shown below.)
RUN TIME
1234
On 12
OFF 11
No.1
Usage status number (See below)
Usage status number
0 ..... Total usage status
1 ..... Current usage status
2 ..... Usage status before first reset
3 ..... Usage status before second reset
||
9 ..... Usage status before eighth reset
Time
Number of times on
Number of times off
HIDDEN SERVICE
FILTER TIME ON
MUTE COLOR BLACK
AIR SENSOR
SOFT RESET
6-12 HIDDEN SERVICE MENU
HIDDEN SERVICE
FILTER TIME ON
MUTE COLOR BLACK
AIR SENSOR
SOFT RESET
Press “ ”.
6-13 RUN TIME window