INSTRUCTION MANUAL
FOR
PRIMAIDE ANALOG INPUT DEVICE
使用说明书
PRIMAIDE 模拟输入装置
日立仪器(大连)有限公司
Hitachi Instruments (Dalian) Co., Ltd.
中国大连市甘井子区辛寨子东街 15
No.15 Xinzhaizi East St. Ganjingzi District Dalian of China
Copyright © Hitachi Instruments (Dalian) Co., Ltd. 2021. 6th Edition, 2021
All rights reserved. Printed in China Part No. 8DD-9442
Before using the instrument, read the safety instructions and
precautions carefully.
Be sure to observe the safety instructions in the manual and the
WARNING/CAUTION labels on the instr ument.
Keep this manual in a safe place nearby so it can be referred to
whenever needed.

Questions and Answers

  • J
    Jessica GrayAug 7, 2025
    What to do if Primaide System Manager cannot connect with AID Hitachi Laboratory Equipment?
    • L
      Lisa HaneyAug 7, 2025
      If the Primaide System Manager is unable to connect with the AID in your Hitachi Laboratory Equipment, here are a few things to try: 1. First, power off the equipment and verify that the CH setting is correct, ensuring there's no overlap with another detector. 2. Next, check the wiring connection to ensure power is being supplied to the AID. 3. Finally, try turning the power on again. If the problem persists after these steps, it may indicate a faulty circuit board.
  • A
    Angela CoxAug 15, 2025
    Why periodic noise appears on acquired signal data Hitachi PRIMAIDE Laboratory Equipment?
    • P
      Peter BatesAug 15, 2025
      If you observe periodic noise appearing on acquired signal data with your Hitachi Laboratory Equipment, the cause may be: 1. An analog signal line that is not grounded: Ensure the line is correctly grounded. 2. A faulty circuit board: If grounding the analog signal input doesn't correct the fault, try turning the power on again. If the fault persists, it may be due to a faulty circuit board.
  • S
    stonejessicaAug 23, 2025
    What to do if DATA BUFFER OVERFLOW in Hitachi PRIMAIDE?
    • E
      Eric BurkeAug 23, 2025
      If you encounter a DATA BUFFER OVERFLOW error with your Hitachi Laboratory Equipment, it is likely due to an error in communication. To resolve this, check the connection with the chromato-data station (CDS) and attempt to reconnect with the CDS.
  • J
    Jamie SmithAug 30, 2025
    How to fix ROM ERROR in Hitachi Laboratory Equipment?
    • A
      alisonsimpsonAug 30, 2025
      If you are getting a ROM ERROR on your Hitachi Laboratory Equipment, it could be due to a faulty operation of the instrument or circuit board. Try turning the power off and on again. If the error continues, it may require professional attention.

Summary

NOTICE

PREFACE

ABOUT THIS MANUAL

IMPORTANT

PRECAUTION ON CE CONFORMITY MARKING

Outlines CE conformity requirements, including EMC, LVD, and RoHS directives.

WARRANTY ON PRODUCT

Details product warranty terms, scope, period, exclusions, and disclaimers for user protection.

INSTALLATION, RELOCATION AND AFTER-SALE TECHNICAL SERVICE

Covers procedures for installation, relocation, and policies for post-sale technical support.

TECHNICAL SEMINARS AND TRAINING FOR CUSTOMERS

Information on available training courses for customers to deepen understanding of analytical instruments.

DISPOSAL OF INSTRUMENT

Provides guidance on the proper disposal of the instrument in compliance with relevant environmental laws.

OTHER PRECAUTIONS

General safety and handling precautions, especially regarding chemicals and samples used with the instrument.

SAFETY SUMMARY

General Safety Guidelines

Essential safety rules and guidelines for operating and handling the instrument safely.

Safety Indications and User Precautions

Details safety indications (DANGER, WARNING, CAUTION, NOTICE) and user precautions.

OUTLINE

Outline of Primaide AID

Describes the key features and capabilities of the Primaide Analog Input Device (AID).

INSTALLATION

Installation to Primaide 1000 Series Unit

Step-by-step guide for physically installing the AID into a Primaide 1000 series unit.

Combination with Primaide 1000 Series

Explains how to integrate the AID with multiple Primaide modules and other HPLC systems.

FUNCTIONS

Name and Function of Each Part

Identifies and explains the purpose of each component on the front panel of the AID.

Specifications

Lists the technical specifications, operational parameters, and performance characteristics of the AID.

TROUBLESHOOTING

Fault Diagnosis and Remedies

Provides a table to identify common symptoms, probable causes, and recommended remedies for AID issues.

INDEX

APPENDIX

DESCRIPTION ON CONTACT SIGNAL COMMUNICATION

Explains the types and usage of contact signals for system communication in the Primaide 1000 series.

Contact Signals in the e-Line Connector

Details the connection and synchronization of contact signals via e-Line connectors.

Individual Contacts of Each Unit

Describes the specific contact signal input and output terminals for individual Primaide units.

Hitachi PRIMAIDE Specifications

General IconGeneral
CategoryLaboratory Equipment
TypeCentrifuge
Maximum Speed15000 rpm
Timer1-99 min
Power Supply50/60Hz