2. Reset Circuit
Timing chart
5
.
0V
4
.
4V
5.0V
4
.
2V
pin of IC501 supply voltage
RES canceling voltage
RES detecting voltage
pin of IC501 output voltage
or
pin of microcomputer
Reset circuit is to initialize the indoor unit microcomputer when switching ON the power or after recovering from power
failure.
Microcomputer operates when
pin of the indoor unit microcomputer (reset input) is "Lo" for resetting and "Hi" for heating.
Waveform of each part when switching ON the power and when shutting down is shown in the Fig. 2-2.
After switching ON the power,
pin of IC501 supply voltage and
pin of microcomputer becomes Hi when DC5V line
rises and reaches approximately 4.4V or higher.
Then, resetting will be cancelled and microcomputer starts operating.
After shutting down the power,
pin of IC501 supply voltage and
pin of microcomputer becomes Lo when DC5V line
falls and reaches approximately 4.2V or lower.
Then, the microcomputer will be in reset condition.
Fig.2-1
Fig.2-2
Voltage
Voltage
C501
R501
C502
5
3
IC501
1
2
5V
R502
R503
13
0V
Reset
Microcomputer
C612
43

Table of Contents

Other manuals for Hitachi RAK-18REF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi RAK-18REF and is the answer not in the manual?

Hitachi RAK-18REF Specifications

General IconGeneral
BrandHitachi
ModelRAK-18REF
CategoryAir Conditioner
LanguageEnglish

Related product manuals