2 General data
Electrical data
TCGB0123 rev.2 - 10/2019
55
2
2.6.3.2 YUTAKI S COMBI
RWD-(2.0-3.0)NRW(S)E-(200/260)S(-K)(-W)
Model
Power
supply
Applicable voltage
Operation mode
RNC
(A)
IPT
(kW)
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RWD-(2.0-3.0NRW(S)E-
(200/260)S(-K)(-W)
1~ 230V
50Hz
253 207
Without electric heater 0.2 0.05 0.2 0.05
With electric heater 13.3 3.05 14.6 3.05
With DHW tank heater 12.2 2.80 12.7 2.80
With electric and DHW tank heaters 25.2 5.80 27.1 5.80
2.6.4 Monobloc system - YUTAKI M
RASM-(2-3)VRE
Model
Power
supply
Applicable voltage
Operation mode
Cooling Heating
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-2VRE
1~ 230V
50Hz
253 207
Without DHW tank heater 4.8 1.00 5.5 1.14 10.6 2.32
With DHW tank heater 4.8 1.00 18.8 3.89 23.1 5.07
RASM-3VRE
Without DHW tank heater 9.4 1.94 8.9 1.84 16.0 3.54
With DHW tank heater 9.4 1.94 22.2 4.59 28.5 6.29
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory
“DHWT-(200/300)S-3.0H2E”.