3 Capacity and selection data
YUTAKI M
TCGB0123 rev.2 - 10/2019
62
3.3 YUTAKI M
3.3.1 Maximum heating capacity table (kW) (Integrated)
Ambient temperature (ºC WB)
-20 -15 -10 -7 -2 2 7 12 15 20 25
System
Water
outlet
temp
(ºC)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
CAP
(kW)
IPT
(kW)
RASM-2VRE
60 3.20 2.29 3.64 2.25 4.00 2.22 5.00 2.17 5.50 1.77 5.66 1.71 5.93 1.61 6.20 1.51
55 4.00 2.42 4.20 2.27 4.48 2.25 4.70 2.24 6.00 2.22 6.30 1.80 6.46 1.68 6.73 1.48 7.00 1.27
50 4.36 2.32 4.60 2.22 4.85 2.13 5.05 2.05 6.15 2.01 6.65 1.71 6.85 1.61 7.17 1.43 7.50 1.25
45 4.00 2.35 4.25 2.30 4.72 2.22 5.00 2.17 5.22 2.00 5.40 1.86 6.30 1.80 7.00 1.63 7.23 1.54 7.62 1.38 8.00 1.23
40 4.15 2.34 4.54 2.24 4.93 2.14 5.17 2.08 5.32 1.86 5.45 1.70 6.40 1.59 7.25 1.48 7.48 1.42 7.87 1.31 8.25 1.21
35 4.30 2.32 4.50 2.14 5.02 2.04 5.33 1.98 5.42 1.73 5.49 1.53 6.50 1.38 7.50 1.34 7.73 1.30 8.12 1.24 8.50 1.18
30 4.50 2.23 4.80 2.09 5.31 1.93 5.62 1.83 5.69 1.65 5.75 1.50 6.70 1.34 7.75 1.30 7.98 1.27 8.37 1.20 8.75 1.14
25 4.70 2.14 5.10 2.04 5.60 1.82 5.90 1.68 5.95 1.56 6.00 1.46 6.90 1.30 8.00 1.27 8.23 1.23 8.62 1.16 9.00 1.09
20 4.90 2.04 5.40 1.99 5.89 1.71 6.18 1.54 6.22 1.48 6.25 1.43 7.10 1.26 8.25 1.24 8.48 1.19 8.87 1.12 9.25 1.05
RASM-3VRE
60 5.10 3.64 5.77 3.46 6.31 3.32 7.50 3.21 8.00 2.76 8.12 2.73 8.31 2.70 8.50 2.66
55 5.30 3.53 5.50 3.44 6.42 3.42 7.15 3.40 9.00 3.30 9.80 3.11 9.85 3.07 9.92 3.01 10.00 2.94
50 5.80 3.39 6.08 3.31 6.83 3.24 7.43 3.18
9.15 3.08 9.90 2.91 10.03 2.88 10.24
2.83 10.45 2.78
45 5.25 3.39 5.70 3.35 6.30 3.24 6.67 3.18 7.24 3.06 7.70 2.96
9.30 2.86 10.00 2.70 10.21 2.68 10.55
2.66 10.90 2.63
40 5.63 3.36 6.19 3.27 6.75 3.17 7.08 3.12 7.64 2.96 8.09 2.83
10.15 2.77 10.75 2.60 10.88 2.59 11.09
2.56 11.30 2.53
35 6.00 3.33 6.25 3.29 7.03 3.14 7.50 3.06 8.04 2.85 8.47 2.69
10.99 2.68 11.50 2.50 11.55 2.49 11.62
2.46 11.70 2.44
30 6.25 3.29 6.52 3.23 7.23 3.08 7.65 3.00 8.36 2.77 8.94 2.58
11.15 2.57 11.65 2.32 11.70 2.30 11.77
2.26 11.85 2.22
25 6.50 3.25 6.80 3.16 7.42 3.02 7.80 2.94 8.69 2.68 9.40 2.48
11.30 2.46 11.80 2.15 11.85 2.11 11.92
2.06 12.00 2.00
20 6.75 3.21 7.08 3.10 7.62 2.97 7.94 2.88 9.09 2.62
10.00
2.40
11.50 2.40 12.00 2.00 12.16 1.97 12.43
1.92 12.70 1.87
? NOTE
CAP: Capacity at maximum compressor frequency (kW). Capacity is valid for difference between water inlet and water outlet of 3-8 ºC.
IPT: Total input power (kW)
The table above shows the input power (IPT) at maximum capacity (CAP). Most of the time, the unit runs at partial load, so that the actual
input is lower.