EasyManua.ls Logo

Hitachi SJ100 - IGBT Test Method

Hitachi SJ100
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SJ100 Inverter
Troubleshooting
and Maintenance
6–15
IGBT Test Method
The following procedure will check the inverter transistors (IGBTs) and diodes:
1. Disconnect input power to terminals [R, S, and T] and motor terminals [U, V, and W].
2. Disconnect any wires from terminals [+] and [RB] for regenerative braking.
3. Use a Digital Volt Meter (DVM) and set it for 1 resistance range. You can check the
status of the charging state of terminals [R, S, T, U, V, W, RB, +, and –] of the inverter
and the probe of the DVM by measuring the charging state.
Table Legend – Almost infinite resistance: Almost zero resistance: ≅ 0 Ω
NOTE: The resistance values for the diodes or the transistors will not be exactly the
same, but they will be close. If you find a significance difference, a problem may exist.
NOTE: Before measuring the voltage between [+] and [–] with the DC current range,
confirm that the smoothing capacitor is discharged fully, then execute the tests.
Part
DVM
Measured
Valu e
Part
DVM
Measured
Val ue
Part
DVM
Measured
Valu e
+ + +
D1 [R] +1 ≅ ∞ Ω D5 [S] [N] 0 TR4 [U] [–] 0
+1 [R] 0 [N] [S] ≅ ∞ Ω [–] [U] ≅ ∞ Ω
D2 [S] +1 ≅ ∞ Ω D6 [T] [N] 0 TR5 [V] [–] 0
+1 [S] 0 [N] [T] ≅ ∞ Ω [–] [V] ≅ ∞ Ω
D3 [T] +1 ≅ ∞ Ω TR1 [U] [+] ≅ ∞ Ω TR6 [W] [–] 0
+1 [T] 0 [+] [U] 0 [–] [W] ≅ ∞ Ω
D4 [R] [N] 0 TR2 [V] [+] ≅ ∞ Ω TR7 [RB] [+] 0
[N] [R] ≅ ∞ Ω [+] [V] 0 [+] [RB] ≅ ∞ Ω
TR3 [W] [+] ≅ ∞ Ω [RB] [–] 0
[+] [W] 0 [–] [RB] 0
[R]
[S]
[T]
TR1 TR2 TR3
[U]
[V]
[W]
[–]
D1 D2 D3
D4 D5 D6
+
[+] [RB][+1]
TR4 TR5 TR6TR7

Table of Contents

Other manuals for Hitachi SJ100