Standard Functions
“A” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FE
(Europe)
-FU
(USA)
–FR
(Japan)
A_01 Frequency source setting 01 01 00
A_02 Run command source setting 01 01 02
A_03 Base frequency setting 50.0 60.0 60.0
A203 Base frequency setting, 2nd
motor
50.0 60.0 60.0
A_04 Maximum frequency setting 50.0 60.0 60.0
A204 Maximum frequency setting, 2nd
motor
50.0 60.0 60.0
A_11 O/OI–L input active range start
frequency
000
A_12 O/OI–L input active range end
frequency
000
A_13 O/OI–L input active range start
voltage
000
A_14 O/OI–L input active range end
voltage
100 100 100
A_15 O/OI–L input start frequency
enable
01 01 01
A_16 External frequency filter time
constant
888
A_20 Multi-speed 0 setting 0 0 0
A220 Multi-speed 0 setting, 2nd motor 0 0 0
A_21 Multi-speed 1 setting 0 0 5
A_22 Multi-speed 2 setting 0 0 10
A_23 Multi-speed 3 setting 0 0 15
A_24 Multi-speed 4 setting 0 0 20
A_25 Multi-speed 5 setting 0 0 30
A_26 Multi-speed 6 setting 0 0 40
A_27 Multi-speed 7 setting 0 0 50
A_28 Multi-speed 8 setting 0 0 60
A_29 Multi-speed 9 setting 0 0 0
A_30 Multi-speed 10 setting 0 0 0
A_31 Multi-speed 11 setting 0 0 0

Table of Contents