EasyManua.ls Logo

Hitachi SJ100 - Page 201

Hitachi SJ100
214 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Settings for Keypad Entry
Appendix B
B–8
Intelligent Terminal Functions
“C” Group Parameters Default Setting
User
Setting
Func.
Code
Name
-FE
(Europe)
-FU
(USA)
–FR
(Japan)
C_01 Terminal [1] function 00 00 00
C_02 Terminal [2] function 01 01 01
C_03 Terminal [3] function 02 16 02
C_04 Terminal [4] function 03 13 03
C_05 Terminal [5] function 18 09 09
C_06 Terminal [6] function 09 18 18
C_11 Terminal [1] active state 00 00 00
C_12 Terminal [2] active state 00 00 00
C_13 Terminal [3] active state 00 00 00
C_14 Terminal [4] active state 00 01 00
C_15 Terminal [5] active state 00 00 00
C_16 Terminal [6] active state 00 00 00
C_21 Terminal [11] function 01 01 01
C_22 Terminal [12] function 00 00 00
C_23 [FM] signal selection 00 00 00
C_24 Alarm relay terminal function 05 05 05
C_31 Terminal [11] active state (–FU) 00
Reserved (FE / FR) 00—00
C_32 Terminal [12] active state (–FU) 00
Terminal [11] active state (–FE /
FR)
00—00
C_33 Alarm relay terminal active state 01 01 01
C_41 Overload level setting Inverter
rated
current
Inverter
rated
current
Inverter
rated
current
C_42 Frequency arrival setting for
accel
0.0 0.0 0.0
C_43 Arrival frequency setting for
decel
0.0 0.0 0.0
C_44 PID deviation level setting 3.0 3.0 3.0
C_81 O input span calibration Factory-set Factory-set Factory-set
C_82 OI input span calibration Factory-set Factory-set Factory-set

Table of Contents

Other manuals for Hitachi SJ100

Related product manuals