Code
Function Name
Default Setting
-FE(CE) -FU(UL)
Change
during operation
(allowed or not)
Setting
during operation
(allowed or not)
Monitored data or setting
Intelligent output terminalsAnalog monitoringLevels and output terminal statusCommunication functionAdjustmentOthers
Intelligent
output terminals
Intelligent input terminals
Terminal (1) active state
Terminal (2) active state
Terminal (3) active state
Terminal (4) active state
Terminal (5) active state
Terminal (6) active state
Terminal (7) active state
Terminal (8) active state
Terminal FW active state
FM signal selection
AM signal selection
AMI signal selection
Digital current monitor reference value
Terminal (11) active state
Terminal (12) active state
Terminal (13) active state
Terminal (14) active state
Terminal (15) active state
Alarm relay terminal active state
Low-current indication signal output mode selection
Low-current indication signal detection level
Overload signal output mode
Overload level setting
Frequency arrival setting for accel.
Frequency arrival setting for decel.
PID deviation level setting
Frequency arrival setting for acceleration (2)
Frequency arrival setting for deceleration (2)
Maximum PID feedback data
Minimum PID feedback data
Over-torque(Forward-driving) level setting
Over-torque(Reverse-regenerating) level setting
Over-torque(Reverse-driving) level setting
Over-torque(Forward-regenerating) level setting
Electronic thermal warning level setting
Alarm code input
Zero speed detection level
Heat sink overheat warning level
Communication speed selection
Node allocation
Communication data length selection
Communication parity selection
Communication stop bit selection
Selection of the operation after communication error
Communication timeout limit before tripping
Communication wait time
Communication mode selection
O input span calibration
OI input span calibration
O2 input span calibration
Thermistor input tuning
Debug mode enable
UP/DOWN memory mode selection
Reset mode selection
Restart mode after reset
FM gain adjustment
AM gain adjustment
C011
C012
C013
C014
C015
C016
C017
C018
C019
C027
C028
C029
C030
C031
C032
C033
C034
C035
C036
C038
C039
C040
C041
C042
C043
C044
C045
C046
C052
C053
C055
C056
C057
C058
C061
C062
C063
C064
C071
C072
C073
C074
C075
C076
C077
C078
C079
C081
C082
C083
C085
C091
C101
C102
C103
C105
C106
00 (RUN: running), 01 (FA1: constant-speed reached), 02 (FA2: set frequency overreached), 03 (OL:
overload notice advance signal (1)), 04 (OD: output deviation for PID control), 05 (AL: alarm signal), 06
(FA3: set frequency reached), 07 (OTQ: over-torque), 08 (IP: instantaneous power failure), 09 (UV:
undervoltage), 10 (TRQ: torque limited), 11 (RNT: operation time over), 12 (ONT: plug-in time over), 13
(THM: thermal alarm signal), 19 (BRK: brake release), 20 (BER: braking error), 21 (ZS: 0 Hz detection
signal), 22 (DSE: speed deviation maximum), 23 (POK: positioning completed), 24 (FA4: set frequency
overreached 2), 25 (FA5: set frequency reached 2), 26 (OL2: overload notice advance signal (2)), 27 (Odc:
Analog O disconnection detection), 28 (OIDc: Analog OI disconnection detection), 29 (O2Dc: Analog O2
disconnection detection), 31 (FBV: PID feedback comparison), 32 (NDc: communication line disconnection),
33 (LOG1: logical operation result 1), 34 (LOG2: logical operation result 2), 35 (LOG3: logical operation
result 3), 36 (LOG4: logical operation result 4), 37 (LOG5: logical operation result 5), 38 (LOG6: logical
operation result 6), 39 (WAC: capacitor life warning), 40 (WAF: cooling-fan speed drop), 41 (FR: starting
contact signal), 42 (OHF: heat sink overheat warning), 43 (LOC: low-current indication signal), 44 (M01:
general-purpose output 1), 45 (M02: general-purpose output 2), 46 (M03: general-purpose output 3), 47
(M04: general-purpose output 4), 48 (M05: general-purpose output 5), 49 (M06: general-purpose output 6),
50 (IRDY: inverter ready), 51 (FWR: forward rotation), 52 (RVR: reverse rotation), 53 (MJA: major failure),
54(WCO: window comparator O), 55(WCOI: window comparator OI), 56 (WCO2: window comparator O2)
(When alarm code output is selected for "C062", functions "AC0" to "AC2" or "AC0" to "AC3" [ACn: alarm
code output] are forcibly assigned to intelligent output terminals 11 to 13 or 11 to 14, respectively.)
00 (output frequency), 01 (output current), 02 (output torque), 03 (digital output frequency), 04 (output
voltage), 05 (input power), 06 (electronic thermal overload), 07 (LAD frequency), 08 (digital current
monitoring), 09 (motor temperature), 10 (heat sink temperature), 12 (general-purpose output YA0)
00 (output frequency), 01 (output current), 02 (output torque), 04 (output voltage), 05 (input power), 06
(electronic thermal overload), 07 (LAD frequency), 09 (motor temperature), 10 (heat sink temperature), 11
(output torque [signed value]), 13 (general-purpose output YA1)
00 (output frequency), 01 (output current), 02 (output torque), 04 (output voltage), 05 (input power), 06
(electronic thermal overload), 07 (LAD frequency), 09 (motor temperature), 10 (heat sink temperature), 14
(general-purpose output YA2)
[◯ ] [◯
= Allowed
×
= Not permitted
]
[◯ ]
0.20 x "rated current" to 2.00 x "rated current" (A)
(Current with digital current monitor output at 1,440 Hz)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
0.0 to 2.00 x "rated current" (A)
00 (output during acceleration/deceleration and constant-speed operation),
01 (output only during constant-speed operation)
0.0 to 2.00 x "rated current" (A)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
0. to 200. (%)
0. to 200. (%)
0. to 200. (%)
0. to 200. (%)
0. to 100. (%)
00(Disabled) / 01(3-bit) / 02(4-bit)
0.00 to 99.99, 100.0 (Hz)
0. to 200.0 (
℃
)
02 (loopback test), 03 (2,400 bps), 04 (4,800 bps), 05 (9,600 bps), 06 (19,200 bps)
1. to 32.
7 (7 bits), 8 (8 bits)
00 (no parity), 01 (even parity), 02 (odd parity)
1 (1 bit), 2 (2 bits)
00 (tripping), 01 (tripping after decelerating and stopping the motor), 02 (ignoring errors),
03 (stopping the motor after free-running), 04 (decelerating and stopping the motor)
0.00 to 99.99 (s)
0. to 1000. (ms)
00(ASCII), 01(Modbus-RTU)
0. to 9999., 1000 to 6553(10000 to 65530)
0. to 9999., 1000 to 6553(10000
〜
65530)
0. to 9999., 1000 to 6553(10000
〜
65530)
0.0 to 999.9, 1000.
(Do not change this parameter, which is intended for factory adjustment.)
00 (not storing the frequency data), 01 (storing the frequency data)
00 (resetting the trip when RS is on), 01 (resetting the trip when RS is off),
02 (enabling resetting only upon tripping [resetting when RS is on])
00 (starting with 0 Hz), 01 (starting with matching frequency), 02 (restarting with active matching frequency)
50. to 200. (%)
50. to 200. (%)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00(NO) / 01(NC)
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
01
01
01
0.00
0.00
3.0
0.00
0.00
100.0
0.0
100.
100.
100.
100.
80.
00
0,00
120.
04
1.
7
00
1
02
0.00
0.
00
00
00
00
100.
100.
00
00
00
00
00
01
00
00
00
00
00
00
00
00
00
00
00
01
01
01
0.00
0.00
3.0
0.00
0.00
100.0
0.0
100.
100.
100.
100.
80.
00
0,00
120.
04
1.
7
00
1
02
0.00
0.
00
00
00
00
100.
100.
×
×
×
×
×
×
×
×
×
×
×
×
○
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
○
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
×
○
○
○
○
○
Rated current of
inverterx 1..0
Rated current of inverterx 1..0
Rated current of inverterx 1..0
Rated current of inverterx 1..0
Factory set
Terminal (11) function
Terminal (12) function
Terminal (13) function
Terminal (14) function
Terminal (15) function
Alarm relay terminal function
C021
C022
C023
C024
C025
C026
01(FA1)
00(RUN)
03(OL)
07(OTO)
40(WAF)
05(AL)
01(FA1)
00(RUN)
03(OL)
07(OTO)
40(WAF)
05(AL)
×
×
×
×
×
×
○
○
○
○
○
○
Meter
adjustment
14