Code
Function Name
Default Setting
-FE(CE) -FU(UL)
Change
during operation
(allowed or not)
Setting
during operation
(allowed or not)
Monitored data or setting
AMI gain adjustment
AM bias adjustment
AMI bias adjustment
Overload setting (2)
O input zero calibration
OI input zero calibration
O2 input zero calibration
Output 11 on-delay time
Output 11 off-delay time
Output 12 on-delay time
Output 12 off-delay time
Output 13 on-delay time
Output 13 off-delay time
Output 14 on-delay time
Output 14 off-delay time
Output 15 on-delay time
Output 15 off-delay time
Output RY on-delay time
Output RY off-delay time
Logical output signal 1 selection 1
Logical output signal 1 selection 2
Logical output signal 1 operator selection
Logical output signal 2 selection 1
Logical output signal 2 selection 2
Logical output signal 2 operator selection
Logical output signal 3 selection 1
Logical output signal 3 selection 2
Logical output signal 3 operator selection
Logical output signal 4 selection 1
Logical output signal 4 selection 2
Logical output signal 4 operator selection
Logical output signal 5 selection 1
Logical output signal 5 selection 2
Logical output signal 5 operator selection
Logical output signal 6 selection 1
Logical output signal 6 selection 2
Logical output signal 6 operator selection
Input terminal response time setting 1
Input terminal response time setting 2
Input terminal response time setting 3
Input terminal response time setting 4
Input terminal response time setting 5
Input terminal response time setting 6
Input terminal response time setting 7
Input terminal response time setting 8
Input terminal response time setting FW
Multistage speed/position determination time
50. to 200. (%)
0. to 100. (%)
0. to 100. (%)
0.0 to 2.00 x "rated current" (A)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0. to 9999., 1000 to 6553 (10000 to 65530)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
0.0 to 100.0 (s)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
Same as the settings of C021 to C026 (except those of LOG1 to LOG6)
00 (AND), 01 (OR), 02 (XOR)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
2ms)
0. to 200. (
×
10ms)
Terminal
other
C107
C109
C110
C111
C121
C122
C123
C130
C131
C132
C133
C134
C135
C136
C137
C138
C139
C140
C141
C142
C143
C144
C145
C146
C147
C148
C149
C150
C151
C152
C153
C154
C155
C156
C157
C158
C159
C160
C161
C162
C163
C164
C165
C166
C167
C168
C169
[◯
= Allowed
×
= Not permitted
]
Adjustment
Output terminal operation functionInput terminal response
Code
Function Name
Default Setting
-FE(CE) -FU(UL)
Change
during operation
(allowed or not)
Setting
during operation
(allowed or not)
Monitored data or setting
Auto-tuning Setting
Motor data selection, 1st motor
Motor data selection, 2nd motor
Motor capacity, 1st motor
Motor capacity, 2nd motor
Motor poles setting, 1st motor
Motor poles setting, 2nd motor
Motor speed constant, 1st motor
Motor speed constant, 2nd motor
Motor stabilization constant, 1st motor
Motor stabilization constant, 2nd motor
Motor stabilization constant, 3rd motor
Motor constant R1, 1st motor
Motor constant R1, 2nd motor
Motor constant R2, 1st motor
Motor constant R2, 2nd motor
Motor constant L, 1st motor
Motor constant L, 2nd motor
Motor constant Io
Motor constant Io, 2nd motor
Motor constant J
Motor constant J, 2nd motor
Auto constant R1, 1st motor
Auto constant R1, 2nd motor
Auto constant R2, 1st motor
Auto constant R2, 2nd motor
Auto constant L, 1st motor
Auto constant L, 2nd motor
Auto constant Io, 1st motor
Auto constant Io, 2nd motor
00 (disabling auto-tuning), 01 (auto-tuning without rotation), 02 (auto-tuning with rotation)
00 (Hitachi standard data), 01 (auto-tuned data), 02 (auto-tuned data [with online auto-tuning function])
00 (Hitachi standard data), 01 (auto-tuned data), 02 (auto-tuned data [with online auto-tuning function])
0.20 to 75.00 (kW)
0.20 to 75.00 (kW)
2, 4, 6, 8, 10 (poles)
2, 4, 6, 8, 10 (poles)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0.001 to 9.999, 10.00 to 80.00 (10.000 to 80.000)
0. to 255.
0. to 255.
0. to 255.
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.01 to 99.99, 100.0 to 655.3 (A)
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.001 to 9.999, 10.00 to 99.99, 100.0 to 999.9, 1000. to 9999.
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.001 to 9.999, 10.00 to 65.53 (
Ω
)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (mH)
0.01 to 99.99, 100.0 to 655.3 (A)
0.01 to 99.99, 100.0 to 655.3 (A)
H001
H002
H202
H003
H203
H004
H204
H005
H205
H006
H206
H306
H020
H220
H021
H221
H022
H222
H023
H223
H024
H224
H030
H230
H031
H231
H032
H232
H033
H233
[◯
= Allowed
×
= Not permitted
]
Control constants
[◯ ]
[◯ ]
100.
0.
20.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
1
1
0
100.
0.
20.
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
1
1
1
1
1
1
1
1
1
0
○
○
○
×
○
○
○
○
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
00
00
00
4
4
1,590
1,590
100.
100.
100.
00
00
00
4
4
1,590
1,590
100.
100.
100.
×
×
×
×
×
×
×
○
○
○
○
○
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
○
○
○
○
○
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Rated current of
inverterx 1..0
Factory set
Factory set
Depending on
motor capacity
H GROUP: MOTOR CONSTANTS FUNCTIONS
Meter
adjustment
15