Chapter 4 Explanation of Functions
 
4 - 119 
Note 6:  The table below lists the functions of the intelligent input terminals and corresponding 
hexadecimal data for 12 command. (For details, see the explanation of the intelligent input terminal 
functions.) 
 
Data (hexadecimal)  Description  Data (hexadecimal)  Description 
0000000000000001 
0000000000000002 
0000000000000004 
0000000000000008 
0000000000000010 
0000000000000020 
0000000000000040 
0000000000000080 
0000000000000100 
0000000000000200 
0000000000000400 
0000000000000800 
0000000000001000 
0000000000002000 
0000000000004000 
0000000000008000 
0000000000010000 
0000000000020000 
0000000000040000 
0000000000080000 
0000000000100000 
0000000000200000 
0000000000400000 
0000000000800000 
0000000001000000 
0000000002000000 
0000000004000000 
0000000008000000 
0000000010000000 
0000000020000000 
0000000040000000 
0000000080000000 
- 
AHD: analog command holding 
CP1: multistage position settings 
selection 1 
CP2: multistage position settings 
selection 2 
CP3: multistage position settings 
selection 3 
ORL: Zero-return limit function 
ORG: Zero-return trigger function 
FOT: forward drive stop 
ROT: reverse drive stop 
SPD: speed / position switching 
PCNT: pulse counter 
PCC: pulse counter clear 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
0000000100000000 
0000000200000000 
0000000400000000 
0000000800000000 
0000001000000000 
0000002000000000 
0000004000000000 
0000008000000000 
0000010000000000 
0000020000000000 
0000040000000000 
0000080000000000 
0000100000000000 
0000200000000000 
0000400000000000 
0000800000000000 
0001000000000000 
0002000000000000 
0004000000000000 
0008000000000000 
0010000000000000 
0020000000000000 
0040000000000000 
0080000000000000 
0100000000000000 
0200000000000000 
0400000000000000 
0800000000000000 
1000000000000000 
2000000000000000 
4000000000000000 
8000000000000000 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
- 
 
(Example) When activating the "forward rotation," "Multispeed 1 setting," and "Multispeed 2 setting" 
settings on the inverter with station No. 01, specify the following in the Data part: 
0x0000000000000001 + 0x0000000000000004 + 0x0000000000000008 = 0x000000000000000D 
Consequently, the whole transmission frame is as follows: 
(STX) |01|02|000000000000000D| (BCC) | (CR) 
- Response frame 
Positive response: See Item (2)-(i) of this section. 
Negative response: See Item (2)-(ii) of this section.