Chapter 4 Explanation of Functions
4 - 159
Register
No.
Function name Function code R/W
Monitoring and setting items Data
resolution
Register
No.
1681h Easy sequence user parameter U (27) P127 R/W 0 to 65530 1
1682h Easy sequence user parameter U (28) P128 R/W 0 to 65530 1
1683h Easy sequence user parameter U (29) P129 R/W 0 to 65530 1
1684h Easy sequence user parameter U (30) P130 R/W 0 to 65530 1
1685h Easy sequence user parameter U (31) P131 R/W 0 to 65530 1
1686h to
2102h
(Reserved) - - Inaccessible -
*1 The following table lists the code data for parameter "H003" (motor capacity selection):
Code data 00 01 02 03 04 05 06 07 08 09 10
Japan or U.S.A. mode
(b085 = 00 or 02)
0.2 kW - 0.4 - 0.75 - 1.5 2.2 - 3.7 -
EU mode (b085 = 01) 0.2 kW 0.37 - 0.55 0.75 1.1 1.5 2.2 3.0 - 4.0
Code data 11 12 13 14 15 16 17 18 19 20 21
Japan or U.S.A. mode
(b085 = 00 or 02)
5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
EU mode (b085 = 01) 5.5 kW 7.5 11 15 18.5 22 30 37 45 55 75
Code data 22 23 24 25 26
Japan or U.S.A. mode
(b085 = 00 or 02)
90kW 110 132 150 160
EU mode (b085 = 01) 90kW 110 132 150 160