EasyManuals Logo

Hitachi Universal Storage Platform V User Manual

Hitachi Universal Storage Platform V
102 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
Functional and Operational Characteristics 3-41
Hitachi Universal Storage Platform V/VM User and Reference Guide
Detection of Power Failure
A
C Input Power Failure Occurs
1 minute
Storage
System
Operating
8 minutes
Data destage process
Power off process
5 minutes
24 hours (CM up to 128 GB)
18 hours (CM 132 GB to 256 GB)
CM and SM are backed up by battery.
200 ms
Storage
System
Operating
CM and SM are backed up by battery.
Ç*2
Destage Mode
USP V only
(battery option
required)
Ç*1
Backup Mode
USP V/VM
Power Failure
Power Failure
Universal Storage Platform V:
48 hours: CM up to 128 GB
36 hours: CM 132 GB to 256 GB
Universal Sto
r
age Platform VM:
36 hours
Notes:
1. When power is recovered after a failure while backup power is being supplied by battery, the storage system
operates depending on the status of the Auto-Power-On JP on the Operator panel:
ENABLE: The storage system is powered on automatically.
DISABLE: The storage system is powered on by operating the Power ON/OFF switch or the PCI.
2. When power is recovered after a failure during the destage process, the destage and power-off processes are
executed.
Figure 3-6 Battery Backup Processes for Power Failure

Table of Contents

Other manuals for Hitachi Universal Storage Platform V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Universal Storage Platform V and is the answer not in the manual?

Hitachi Universal Storage Platform V Specifications

General IconGeneral
BrandHitachi
ModelUniversal Storage Platform V
CategoryStorage
LanguageEnglish

Related product manuals