Do you have a question about the Hitachi Virtual Storage Platform 5000 Series and is the answer not in the manual?
| Maximum Raw Capacity | Up to 69 PB |
|---|---|
| Model | Virtual Storage Platform 5000 series |
| Storage Controller Type | Active-Active controller architecture |
| Drive Types Supported | SSD, SAS HDD, NVMe SSD |
| RAID Levels Supported | RAID 1, RAID 5, RAID 6, RAID 10 |
| Data Reduction Features | Deduplication, Compression |
| Host Interface | Fibre Channel, iSCSI, FCoE, NVMe-oF |
| Cache Memory | Up to 6 TB (model dependent) |
| Supported Protocols | FC, iSCSI, FCoE, NVMe-oF |
| Maximum IOPS | Up to 33 million |
| Operating System | Hitachi Storage Virtualization Operating System (SVOS) |
| Supported Operating Systems | Windows, Linux, VMware |
| Management Software | Hitachi Ops Center |
| Redundancy | Fully Redundant Hardware |
Details safety and environmental guidelines for operating the storage system.
Specifies the target audience for this hardware guide.
Indicates the microcode version this document applies to.
Provides information on updates, corrections, or restrictions for the product.
Lists modifications made in the current document revision.
Explains typographic conventions used throughout the document.
Defines how storage capacities are calculated and presented.
Guides users on how to find additional product documentation.
Provides contact information and resources for technical support.
Instructions on how to submit feedback or comments on the document.
Highlights the key capabilities and benefits of the VSP 5000 series.
Lists the technical specifications of the VSP 5000 series storage systems.
Describes the overall hardware architecture and constituent parts of the system.
Details the components and layout of the controller chassis.
Explains the different components and LEDs on the controller board.
Describes the 10-Gbps iSCSI board, its ports, and LEDs.
Details the 4-port Fibre Channel board, its port assignments.
Explains the back-end module, its connectors, and status LEDs.
Describes the fabric-acceleration module and its status indicators.
Covers the different types of drive boxes and their components.
Lists and describes the supported data storage drives.
Details the node interconnect switch and its components.
Describes the interconnect switch and its port status indicators.
Explains the service processor, its functions, and controls.
Provides specifications and configuration details for the Ethernet switch.
Identifies the location and meaning of LEDs on the high availability node.
Lists the core technical specifications of the storage system.
Provides power consumption, heat output, and weight details.
Details power requirements, inrush current, and voltage specifications.
Outlines the operating, non-operating, and shipping environmental conditions.
Describes vibration specifications for operation and non-operation.
Explains the storage system's idle mode and its conditions.
Provides step-by-step instructions for normal power operations.
Details the steps to power on the storage system correctly.
Details the steps to safely power off the storage system.
Outlines the process for emergency power off.
Details how to restore power after an emergency shutdown.
A checklist to verify site readiness for installation.
Covers planning activities for hardware configuration and cabling.
Discusses factors for choosing and preparing the installation site.
Specifies requirements for floor space, cutouts, and clearance.
Defines the floor load capacity required for the system.












Loading...