Chapter 3: Specifications
The storage system use the following specications.
The Hitachi Virtual Storage Platform 5000 series(VSP 5000 series) storage systems are
designed to operate in a controlled environment such as a data center. The following
tables provide the environmental, electrical, and physical requirements and
specications for the storage systems.
Storage system specifications
The following table lists the technical specications of the Hitachi Virtual Storage
Platform 5000 series storage system.
Item Specification
System 2.5-inch SAS
HDD/SSD
Maximum number of
drives
2-node system: 768
4-node system: 1,536
6-node system: 2,304
3.5-inch SAS
HDDs
Maximum number of
drives
2-node system: 384
4-node system: 768
6-node system: 1,152
Number of
FMDs
Maximum number of
drives
2-node system: 192
4-node system: 384
6-node system: 576
Number of
NVMe drives
Maximum number of
SSDs
2-node system: 96
4-node system: 192
6-node system: 288
Maximum number of
SCM drives
2-node system: 33
4-node system: 66
6-node system: 99
RAID group
conguration
RAID 6
6D+2P
14D+2P
Chapter 3: Specications
Hitachi Virtual Storage Platform 5000 Series Hardware Guide 55

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Virtual Storage Platform 5000 Series and is the answer not in the manual?

Hitachi Virtual Storage Platform 5000 Series Specifications

General IconGeneral
BrandHitachi
ModelVirtual Storage Platform 5000 Series
CategoryStorage
LanguageEnglish

Related product manuals