[Difference between each control]
Ø Control performance
Item SLV mode V2 mode
Speed linearity <1 % <0.01 %
Speed fluctuation <1 % <0.01 %
Control range 1 : 50 1 : 100
Speed response 15 rad/s 60 rad/s
Torque control range 1 : 50 1 : 100
Torque response 50 rad/s 500 rad/s
Ø Torque performance at low speed
Item SLV control 0-SLV control V2 control
Down sized motor 150% or more 150% or more 150% or more
Same kW motor 100% or more 100% or more 100% or more
s These are guaranteed minimum values with a Hitachi standard induction motor. Actual capability is greater.
Ø Torque performance at 0Hz
Item 0-SLV control V2 control
Down-sized motor 150% or more
with a small slip
150% or more
with standstill
Same kW motor 100% or more
with a small slip
100% or more
with standstill
s This has been confirmed using Hitachi standard induction motor and J2 motor (for V2 control).
s Note: These are representative values only.
s
Percentages are relative to base speed

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi Vector Control with the SJ300 Inverter and is the answer not in the manual?

Hitachi Vector Control with the SJ300 Inverter Specifications

General IconGeneral
BrandHitachi
ModelVector Control with the SJ300 Inverter
CategoryInverter
LanguageEnglish

Related product manuals