49
Monitoring functions
NOTE: Mark in b031=10 shows the accessible parameters when b031 is set 10, high
level access.
* Please change from" (Basic display)" to " (Full display)" in parameter (Function
code display restriction), in case some parameters cannot be displayed.
IMPORTANT
Please be sure to set the motor nameplate data into the appropriate parameters
to ensure proper operation and protection of the motor:
b012 is the motor overload protection value
A082 is the motor voltage selection
H003 is the motor kW capacity
H004 is the number of motor poles
Please refer to the appropriate pages in this guide and the Instruction Manual for further details.
d Function
Run
Mode
Edit
Units
Func.
Code
Name
Description

Output frequency monitor
Real time display of output frequency
to motor from
0.0 to 400.0(1000.)
*1
Hz
If  is set high, output frequency
() can be changed by up/down
key with d001 monitoring.
Hz

Output current monitor
Filtered display of output current to
motor, range is
0 to 655.3 ampere (~99.9 ampere for
1.5kW and less)
A

Rotation direction monitor
Three different indications:
Forward
Stop
Reverse

Process variable (PV),
PID feedback monitor
Displays the scaled PID process
variable (feedback) value ( is
scale factor),
0.00 to 10000
% times
constant

Intelligent input
terminal status
Displays the state of the intelligent
input terminals:
ON
OFF
7 6 5 4
3
2 1
Terminal numbers