Intelligent output
terminal status
Displays the state of the intelligent
output terminals:
Scaled output frequency
monitor
Displays the output frequency scaled
by the constant in .
Decimal point indicates range:
0 to 3999
Displays the actual frequency, range
is -400 (-1000) to 400 (1000)
*1
Hz
Displays the torque command, range
is -200 to 200 %
Displays the torque bias value, range
is -200 to 200 %
Displays the output torque, range is
-200 to 200 %
Voltage of output to motor,
Range is 0.0 to 600.0V
Displays the input power, range is 0
to 999.9 kW
Displays watt-hour of the inverter,
range is 0 to 9999000
Displays total time the inverter has
been in RUN mode in hours.
Range is 0 to 9999 / 1000 to 9999 /
100 to 999 (10,000 to 99,900)
Elapsed power-on time
monitor
Displays total time the inverter has
been powered up in hours.
Range is 0 to 9999 / 1000 to 9999 /
100 to 999 (10,000 to 99,900)
Heat sink temperature monitor
Temperature of the cooling fin, range
is -20 to 150
Displays the state of lifetime of
electrolytic capacitors on the PWB
and cooling fan.
Program counter monitor
[EzSQ]
Program number monitor
[EzSQ]
Result of EzSQ execution, range is
–2147483647 to 2147483647
Result of EzSQ execution, range is
–2147483647 to 2147483647
Result of EzSQ execution, range is
–2147483647 to 2147483647