Chapter 7 Setting
16
7.1 Installation of the GSDML File
It is necessary to install the GSDML File to your PC tool (Engineering tool) of PROFINET IO controller
to use WJ-PN. GSDML file is a file that contains specific information of the PROFINET IO devices.
Please inquire to the nearest business contact about the GSDML file.
7.2 Parameter settings of WJ200 / WL200
WJ-PN needs the parameter settings of WJ200 / WL200, which shows the following table.
Concerning the operating of the system, it is necessary to refer to the instruction manual of the
inverter and the QRG of this option. Please perform appropriate settings as needed.
Parameter settings
Function
code
Name
Value and description
Default
Run
mode
edit
High level
access
mode
A001
Frequency source
04: option
02
×
×
A002
Run command source
04: option
02
×
×
A004
Maximum frequency
Optional
Settable from the base
frequency to 400(580) Hz
60.0
×
×
A038
Jog frequency
Optional
Defines limited speed for
jog, range is from start
frequency to 9.99 Hz
6.00
A039
Jog stop mode
Optional
Define how end of jog
stops the motor; six
options:
00 : Free-run stop (invalid
during run)
01 : Controlled
deceleration (invalid
during run)
02 : DC braking to stop
(invalid during run)
03 : Free-run stop (valid
during run)
04 : Controlled
deceleration (valid during
run)
05 : DC braking to
stop(valid during run)
04
×