Chapter 10 WJ-PN Specification
62
10.1 WJ-PN Specifications
WJ200 / WL200 Series Option Board
*1
Ambient operating
temperature
-10 to 50[degree] (no icing or condensation)
Ambient operating humidity
-20 to 65°C (no icing or condensation)
5.9[m/s
2
] (0.6[G]) at 10 to 55[Hz]
500[V
AC
] (between isolated circuits)
Conformance to EMC and
electrical safety standards
EN61800-3: 2004 / A1:2012 (2014/30/EU) First
environment, Category C1
*2
EN61800-5-1: 2007 (2014/35/EU)
Auto negotiation
(100BASE-TX (IEEE802.3) only)
100BX-TX supported (category 5e or higher)
STP cable (straight or cross allowed)
Distance between nodes: 100[m] max
Standard telegram 1
WJ-PN telegram 103 (same as PPO3 of PROFIdrive
version 2)
WJ-PN telegram 104 (same as PPO4 of PROFIdrive
version 2)
WJ-PN telegram 105 (like PPO5 of PROFIdrive
version 2)
From P160 to P179 of WJ200 / WL200 parameters
Only jogging 1 is supported.
Note1: When WJ-PN is attached to WJ200 / WL200, functional safety is not supported. Please refer
to “5.3 A system configuration of the PROFINET” for details.
Note2: C1 only when installed in a metal cabinet, otherwise C2.