Chapter 9 Errors and Remedies
57
9.3 Hint of the action by the combination with the WJ200
/ WL200
The inverter WJ200 / WL200 series has various items (parameters). Attention is necessary
because driving movement of the PROFINET changes depending on the items (parameters).
An example is shown below.
9.3.1 A002 (Run command source)
The behavior of WJ200 / WL200 is as follows when changed from OFF (shut off) to ON (enabled to
drive) when WJ200 / WL200 is used with Dip-Switch in the position to activate functional safety.
If either GS1 signal or GS2 signal is turned to OFF (shut off), the condition of the output is
continued to an interruption state.
It is to be known that approval by a third party for “STO function is void even if the safety
function is activated with the Dip-Switch in the position to select functional safety (STO) when WJ-PN
is attached to WJ200 / WL200.
Please refer to [Functional Safety of WJ200 / WL200] in [Chapter 2.1 Outline of product].
Contents
OFF(inverter output is forbidden)→ON(inverter output is
allowed)
01 (control circuit terminal
block)
Driving restart
02 (digital operator)
stop (driving does not restart)
03 (Modbus)
Driving restart
04 (option)
Driving restart