EasyManua.ls Logo

Hitachi WL200 Series - Page 80

Hitachi WL200 Series
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix PROFINET Object List
74
Index
Sub-
inde
x
Register
number
Size
[bite]
Functio
n
code
Name
R/W
Description and range
Resolutio
n
WJ200
only
1018
0x6F
0x124A
02
(UINT)
A056
DC braking
/ edge or
level
detection
for [DB]
input
R/W
00: edge detection
01: level detection
-
1018
0x70
0x124B
02
(UINT)
A057
DC braking
force at
start
R/W
0 to 100
1[%]
1018
0x71
0x124C
02
(UINT)
A058
DC braking
time at start
R/W
0 to 600
0.1[s]
1018
0x72
0x124D
02
(UINT)
A059
Carrier
frequency
during DC
braking
R/W
20 to 150
0.1[kHz]
2018
0x74
0x124F
04
(UDINT)
A061
Frequency
upper limit
R/W
0 or frequency lower
limit (A062) to the
maximum frequency
(A004)
0.01[Hz]
2018
0x76
0x1251
04
(UDINT)
A062
Frequency
lower limit
R/W
0 or start frequency
(b082) to frequency
upper limit (A061)
0.01[Hz]
2018
0x78
0x1253
04
(UDINT)
A063
Jump
frequency
(center) 1
R/W
0 to 40000
0.01[Hz]
1018
0x7A
0x1255
02
(UINT)
A064
Jump
frequency
width
(hysteresis)
1
R/W
0 to 1000
0.01[Hz]
2018
0x7B
0x1256
04
(UDINT)
A065
Jump
frequency
(center) 2
R/W
0 to 40000
0.01[Hz]
1018
0x7
D
0x1258
02
(UINT)
A066
Jump
frequency
width
(hysteresis)
2
R/W
0 to 1000
0.01[Hz]
2018
0x7E
0x1259
04
(UDINT)
A067
Jump
frequency
(center) 3
R/W
0 to 40000
0.01[Hz]

Other manuals for Hitachi WL200 Series