EasyManua.ls Logo

Hitachi WL200 Series - Page 96

Hitachi WL200 Series
131 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix PROFINET Object List
90
Index
Sub-
inde
x
Register
number
Size
[bite]
Functio
n
code
Name
R/W
Description and range
Resolutio
n
WJ200
only
1019
0x7E
0x1357
02
(UINT)
b084
Initializatio
n mode
(parameters
or trip
history)
R/W
00: initialization
disabled
01: clears trip history
02: initializes all
parameters
03: clears trip history
and initialize all
parameters
04: clears tip history
and initializes all
parameters and EZSQ
program
-
1019
0x7F
0x1358
02
(UINT)
b085
Country for
initialization
R/W
00: mode 0
01: mode 1
-
1019
0x80
0x1359
02
(UINT)
b086
Frequency
scaling
conversion
factor
R/W
1 to 9999
0.01
1019
0x81
0x135A
02
(UINT)
b087
STOP key
enable
R/W
00: enabled
01: disabled
02: enabled only reset
-
1019
0x82
0x135B
02
(UINT)
b088
Restart
mode after
FRS
R/W
00: restart from 0[Hz]
01: restart form
frequency detected
from real speed of
motor (frequency
matching)
02: restart from
frequency detected
from real speed of
motor (active
frequency matching)
-
1019
0x83
0x135C
02
(UINT)
b089
Automatic
carrier
frequency
reduction
R/W
00: disabled
01: enabled,
depending on the
output current
02: enabled,
depending on the
heat-sink temperature
-
1019
0x84
0x135D
02
(UINT)
b090
Dynamic
braking
usage ratio
R/W
0 to 1000
0.1[%]

Other manuals for Hitachi WL200 Series