63
PMEN0645 rev.0 - 04/2023
8
COMMISSIONINGPROCEDURE
COMMISSIONING
8.2.4 Checking the refrigerant circuit
Check to ensure that the stop valves on the gas and liquid lines are fully open.
Check that the size of the piping and the refrigerant charge comply with the applicable
recommendaons.
Check the inside of the unit for refrigerant leakage. If there is a refrigerant leak, call your dealer.
Check outdoor unit commissioning procedure manual.
8.3 Commissioning procedure
This procedure is valid regardless of what opons are on the module.
When installaon is complete and all necessary sengs (Dip-switches in PCBs and user
controller conguraon) have been carried out, close the electrical box and place the cabinet as
shown in the manual.
Make the start-up wizard conguraon in the user controller.
Make a test run as shown in item “8.4 Test run / air purge”.
Aer test run is completed, start the enre unit or the selected circuit by pressing the OK buon.
   Inial start-up at low outdoor ambient temperatures
During commissioning and when water temperature is very low, it is important for the water to be
heated gradually. Addional oponal funcon can be used for starng at low water temperature
condions: Screed drying funcon:
The screed funcon is used exclusively for the process of drying a newly applied screed to
the oor heang system. The process is based on EN-1264 par 4.
When user acvates screed funcon, the water set point follows a predetermined schedule:
1 Water set point is kept constant at 25°C for 3 days.
2 Water set-point is set to the maximum Heang supply temperature (but always limited to ≤ 55°C)
for 4 days.
! CAUTION
Heang at lower water temperatures (approximately 10°C to 15°C) and lower outdoor ambient
temperatures (<10°C) can be damaging to the heat pump when defrosng.
As a result, Heang up to 15°C when outdoor temperature is lower than 10°C is performed by
the Electrical Heater.
NOTE
In case of Heater Forced OFF (by oponal dip switch seng) these condion is not performed and
heang is performed by Heat Pump. Hitachi is not responsible for its operaon.

Table of Contents

Other manuals for Hitachi YUTAKI S COMBI Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi YUTAKI S COMBI Series and is the answer not in the manual?

Hitachi YUTAKI S COMBI Series Specifications

General IconGeneral
TypeAir-to-Water Heat Pump
Energy Efficiency Class (Cooling)A++
RefrigerantR32
Operating Temperature Range (Heating)-20°C to 35°C
Energy Efficiency Class (Heating)A+++
Integrated DHW Tank190 liters
Dimensions (Indoor Unit)Varies by model
Dimensions (Outdoor Unit)Varies by model
Weight (Indoor Unit)Varies by model
Weight (Outdoor Unit)Varies by model
Operating Temperature Range (Cooling)+10°C to +46°C

Related product manuals