14
TROUBLESHOOTING
Problem: Machine won’t release at the end of time.
Q. Do you hear the solenoid click when the timer reaches zero?
If no – with a volt meter check
for voltage across the solenoid
coil wires when the timer reaches
zero. If you have line voltage
(120V or 220V) then the solenoid
is bad and needs replaced. If
there is no line voltage the control-
ler is bad and needs replaced.
If yes – Reduce the
pressure on the ma-
chine and see if it will
release then.
If no- try manually releasing
the machine with the manual
release lever.
If Yes – remove the solenoid cover
and inspect the connecting pin on
the solenoid to see if it is intact or
broken. If broken, replace the pin.
If no – inspect the latch
mechanism to see if it is
jammed.
Does reducing the pressure x the problem?
Does it manually release?
If no – does the display read
“Pressure High”?
If yes – Try increasing the pressure
If no- Call technical support.
800-835-0606
If yes - Call technical support.
800-835-0606
If yes – try reducing the pressure
Does increasing the pres-
sure x the problem?
Problem: Platen pressure indicator not working properly.
Q. Does the platen pressure display show “0” when the
press is locked down?
Does reducing the
pressure x the problem?