EasyManuals Logo

HKC HQ Series User Manual

HKC HQ Series
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
HQ Series Quarter-turn Electric Actuator
Installation Operation& Maintenance Manual
Doc No. : HumG-HQ-21 Rev2 Page 22 / 26 Valve Automation Leader, HKC
Appendix I: HQ series Coding System
[Note: Coding system was consolidated from each model’s ------ 15 Rev0]
Example : HQ – A a b c d e f g
Model Name Code (as below)
Code : A = Torque output, XXX
008: 80 Nm, 010: 100 Nm, 015: 150 Nm, 020: 200 Nm, 030: 300 Nm, 050: 500 Nm, 060: 600 Nm,
080: 800 Nm, 120: 1200 Nm, 200: 2000 Nm, 270: 2700 Nm, 300: 3000 Nm, [350: 3500 Nm, 400:
4000 Nm, 600: 6000 Nm, 900: 9000 Nm ----- 21 Rev0]
Code : a = Enclosure
1 :Weather proof (NEMA type 4/4X/6, IP67 Include CSA ordinary location item)
2 : Submersible (IP 68, 10m / 72 hr)
3 : Flameproof [(CSA, IECEx, ATEX, KCs, EAC; Ex db IIB T4 Gb) –17Rev0]
4 : Dust ignition proof (IECEx, ATEX, KCs; Ex tb IIIC T135℃ Db)
b = Input Voltage
1 : 110 V ac / 1 Ph
2 : 220 V ac / 1 Ph
3 : 220 V ac / 3 Ph (Except HQ-008, HQ-010)
[4 : 380 V ac / 3 Ph
5 : 440 V ac / 3 Ph --- 18 Rev1]
6 : 460 V ac / 3 Ph (Except HQ-008, HQ-010)
7 : 24 V dc (Except HQ-050 ~ HQ-300)
8 : 24 V ac/dc (Except HQ-050 ~ HQ-300)
9 : 12V dc (Except HQ-015 ~ HQ-300)
A : 12V ac/dc (Except HQ-015 ~ HQ-300)
c = Option 1 : Control Unit
0 : without control unit
[1 : ICU (Intelligent Digital Control Unit : LCU-C+IMS+Auto Phase Discriminator)
2 : SICU(Semi-Integral Control Unit : LCU-B+IMS+Phase Protect Indicator)
3 : RBP
(Rechargeable Battery Backup* this option excludes from explosion proof)--- 17 Rev0]
[4 : IMS (Integral Magnetic Starter)
5 : LCU-Z (
this option excludes from explosion proof)
--------- 19 rev0]
d = Option 2 : Software
0 : [without software --- 16 Rev1]
1 : PIU (Potentiometer Unit : 0~1kΩ)
2 : CPT (Current Position Transmitter : 4~20mA)
3 : PCU (Proportional Control Unit : IN/OUT 0~10V, 4~20mA)
[4 : ModBus (Communication protocol)
5 : ProfiBus (Communication protocol) --- 19 Rev0]
e = Option 3 : Additional Switches
0 : [without additional switches --- 16 Rev1]
1 : 2ALS (Additional Limit Switches)
2 : 2ATS (Additional Torque Switches)
f = Option 4 : Signal Lamp / 90° mounting Plate
0 : without LPA
1 : SLU (Signal Lamp Unit)
2 : LPA (Lever Plate Actuator 90°)
3 : SLU + LPA
g = Option 5 : Fire Proofing Actuator
0 : without FPA 1 / FPA 2
1 : FPA 1 (Fire Proofing Actuator : 1,050 ± 5℃ / 50min)
2 : FPA 2 (Fire Proofing Actuator : 250 ± 5℃ / 150min)