3.3. CHEMICAL SENSOR START-UP
All below-mentioned steps must be carried out by service tech-
nicians qualified by Hobart. Make sure to observe all precau-
tionary measures required when working near live components.
Before removing the housing, make sure the machine is voltage-free.
Carry out hose filling SF1 and SF2 via the customer menu (see
section 3.4.).
Watch both hoses until the sensor-operated filling is completed.
The control LEDs must light up. If necessary, readjust the potenti-
ometers (increase setting).
Factory setting: potentiometer setting for detergent = 3
Factory setting: potentiometer setting for rinse aid = 5
Activate the sensor by using CH = “1” in the customer menu (see
section 8.7.).
Rinse Aid
Detergent
3. START-UP