Page #62 background imageLoading...
Page #62 background image
OM-2244 / Operation and Maintenance Manual
DCS-600/ Series 500082 / Solid State Transformer-Rectifiers
December 15, 2014
Chapter 4-1
Page 2
(1) FIGURE-ITEM NO. Column
This column lists the figure number of the illustration applicable to a particular parts list and also
identifies each part in the list by an item number. These item numbers also appear on the
illustration. Each item number on an illustration is connected to the part to which it pertains by a
leader line. Thus the figure and item numbering system ties the parts lists to the illustrations and
vice versa. The figure and index numbers are also used in the numerical index to assist the user
in finding the illustration of a part when the part number is known.
(2) ITW GSE PART NUMBER Column
All part numbers appearing in this column are ITW GSE numbers. In all instances where the part
is a purchased item, the vendor’s identifying five-digit code and his part number will appear in the
“NOMENCLATURE” column. Vendor parts, which are modified by ITW GSE, will be identified as
such in the “NOMENCLATURE” column. In case ITW GSE does not have an identifying part
number for a purchased part, the “ITW GSE PART NUMBER” column will reflect “No Number”
and the vendor’s number will be shown in the “NOMENCLATURE” column. Parts manufactured
by ITW GSE will reflect no vendor or part number in the “NOMENCLATURE” column.
(3) NOMENCLATURE Column
The item identifying name appears in this column. The indenture method is used to indicate item
relationship. Thus, components of an assembly are listed directly below the assembly and
indented one space. Vendor codes and part numbers for purchased parts are also listed in this
column when applicable. ITW GSE modification to vendor items is also noted in this column.
(4) EFF (Effective) Column
This column is used to indicate the applicability of parts to different models of equipment. When
more than one model of equipment is covered by a parts list, there are some parts that are used
on only one model. This column is used for insertion of a code letter A, B, etc., to indicate these
parts and to identify the particular model they are used on. Since this manual covers only one
generator set specification, this column is not used in this manual.
EFF
Code
Part & Dash
Number
Mounting
CE
Certified
Input
Voltage
Input
Frequency
Output
Voltage
Output
Current
A
DCS600T60208
Trailer
--
220/230/460
60 Hz.
28.5
VDC
600 A
B
DCS600T50380
Trailer
--
220/380
50 Hz.
28.5
VDC
600 A
C
DCS600T6O575
Trailer
--
230/460/575
60 Hz.
28.5
VDC
600 A
E
DCS600T50380CE
Trailer
Y
220/380
50 Hz.
28.5
VDC
600 A
F
DCS600S60208
Stationary
--
208/230/460
60 Hz.
28.5
VDC
600 A
G
DCS600S50380
Stationary
--
220/380
50 Hz.
28.5
VDC
600 A
H
DCS600S50380CE
Stationary
Y
220/380
50 Hz.
28.5
VDC
600 A
J
DCS600B60208
Bridge
--
208/230/460
60 Hz.
28.5
VDC
600 A
K
DCS600B60380
Bridge
--
220/380
50 Hz.
28.5
VDC
600 A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hobart GPU-600 Series and is the answer not in the manual?

Hobart GPU-600 Series Specifications

General IconGeneral
BrandHobart
ModelGPU-600 Series
CategoryTransformer
LanguageEnglish

Related product manuals