2
Flux Cored
E71T-11
(DCEN)
Solid Wire
ER70S-6
(DCEP)
Solid Wire
ER70S-6
(DCEP)
Stainless
Steel
(DCEP)
Aluminum**
(DCEP)
Good for windy or
outdoor applications
Produces less spatter.
Better bead appearance.
1/30 2/30
2/20
3/50
3/35
3/30
3/40
4/30
3/40
3/20
4/70
4/40
4/40
4/40
4/35
4/45
4/35
4/50*
4/30
2/30
2/20
1/25
3/40
2/30
3/25
3/30
3/20
4/25
4/503/402/30
—4/303/102/15
4/90**3/90**
2/30
——
CFH
Settings are approximate. Adjust as required. Thicker materials can be
welded using proper technique, joint preperation and multiple passes.
Recommended Voltage and Wire Speed Settings for thickness of metal being welded.
Number on left of slash is Voltage Setting/Number on right of slash is Wire Feed Setting.
*Multiple passes required. **Aluminum wire is soft so feedability is not as good. Make sure that hub tension is not too tight and keep the torch as straight as possible. A “push angle” for the torch is recommended.
Match feed roll groove to diameter of wire being used.
Set tension knob setting to 3 at start.
Adjust tension per instructions in the manual.
CAUTION! Do not change voltage switch
position while welding. See owners manual
for more information.
Wire speed listed is a starting value only. Wire speed setting can be
fine-tuned while welding. Wire speed also depends on other variables
such as stick out, travel speed, weld angle, cleanliness of metal, etc.
Handler 140 Welding Guide
Control Panel
1. Power Switch
2. Wire Speed Control
3. Voltage Control Switch
1
2
3
Certified by Canadian Standards Association to both the Canadian and U.S. Standards.
*
CSA rating.
Specifications
(SUBJECT TO CHANGE WITHOUT NOTICE.)
Rated Output
90 A, 19 VDC,
at 20% Duty Cycle
63 A, 21 VDC
at 20% Duty Cycle*
Max. Open-
Circuit Voltage
28 V
Wire Feed
Speed Range
40 700 IPM
50 740 IPM
at no load
Current
Range
25 140 A
Amps Input at Rated Output, 60 Hz, 1-Phase
115 V KVA KW
20 2.9 2.5
15* 2.2* 1.77*
Dimensions
H: 12-3/8 in. (315 mm)
W: 10-5/8 in. (270 mm)
D: 19-1/2 in. (495 mm)
Net
Weight
57 lb.
(26 kg)

Other manuals for Hobart Handler 140

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hobart Handler 140 and is the answer not in the manual?

Hobart Handler 140 Specifications

General IconGeneral
Input Voltage115V
Welding Amperage Range25-140 A
Duty Cycle20% @ 90A
Wire Feed Speed Range40-700 IPM
Weldable MaterialsMild Steel, Stainless Steel, Aluminum
Weight57 lbs
ProcessesMIG (GMAW), Flux-Cored (FCAW)
Input Current20A
Welding Thickness24 ga. - 1/4 in.
Input PhaseSingle Phase
Maximum Open Circuit Voltage28V
Wire Size Range0.023 - 0.035 in