BA-21870-001-GB 08.10.2010 13
GB
4.4.3. DETERGENT DIRECT INJECTION (UP/UPT ONLY)
! Push the Program button
➁
again.
• The upper display
➅
shows ”SF3”,
• The lower display
➄
shows “0”.
! Pushing the ON/OFF button
➀
activates the hose priming for 20
seconds.
! Check the fill level thereafter, and if necessary, repeat.
! Each cycle can be interrupted by pushing the ON/OFF button again.
4.4.4. TERMINATION OF HOSE PRIMING
! Open door and close it again, or do not press any button for
15 seconds!
4.5. SOFTENER (OPTIONAL)
NOTE: For the first run, the softener has to be filled with regeneration
salt and potable water.
Attention:
Filling the salt reservoir with cleaning agent will damage the
water softener.
! Open the door.
! Unscrew the softener lid and fill with 2 kg of “Granular regeneration
salt” using a funnel (do not use salt tablets).
! Fill up the softener with potable water (only at the first run).
! Clean seal and rim of softener lid carefully, before closing the lid.
! Close lid and tighten.
! In order to prevent corrosion, it is necessary to remove any
salt residues from tank bottom.
! Adjust the water hardness according to section 9.3.!
! When the Salt indicator
➆
illuminates during operation, the soft-
ener has to be refilled with regeneration salt.
! There will be a slight delay before the salt light extinguishes after
refill.
4. START UP