Sape Weight Application
When valid results become available in a hwm mode, the sape is configured for weight application. When
the sape is now removed from the home position the sape position is checked against the stored offset
positions. The sape arm is used to apply stick on weights only. If a stick on weight is required for a
plane, the value of the weight is above the threshold and the wheel is rotated so that the green
application led is lit for that plane, the machine will beep when the sape arm is moved to within +/-
1.5mm of the weight position. While the sape is in this position the appropriate weight led will flash.
Moving out of this position will stop the led from flashing.
Application mode can be canceled by pressing the offset key (as described above) when the
sape is in the home position.