EasyManua.ls Logo

Honda CB650FA 2016 - Main Fuse

Honda CB650FA 2016
127 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
#
Main Fuse
1.
Remove the seat. 2 P. 60
2.
Disconnect the wire connector of the
starter magnetic switch.
3.
Pull the main fuse out and check for a
blown fuse. Always replace a blown fuse
with a spare fuse of the same rating.
u Spare main fuse is provided in the
starter magnetic switch.
4.
Reinstall parts in the reverse order of
removal.
NOTICE
If a fuse fails repeatedly, you likely have an
electrical problem. Have your motorcycle
inspected by your dealer.
20161220114015_32MJED100_eng_BOOK Page 104 Tuesday, December 20 2016 11:43:47 JST
Electrical Trouble u Blown Fuse
Troubleshooting
101
Starter magnetic
switch
Main fuse
Wire connector