LTEM-P Installation and Setup Guide
18
Additional Notes When Using the Dialer Capture Module
The Dialer Capture module supports only one-way communications (from the control panel to the
central station). For those control panels that support two-way voice communications,
speakerphone, paging, follow-me, etc., these features will no longer be available. The control panel
must be programmed for one-way communications only.
Since Dialer Capture module supports only one-way communications (from the control panel to the
central station), the Resideo Compass Downloader cannot be used.
In the event the communicator loses power, the module would not be able to generate a fault
trigger to the control panel and set an alarm. In this case, after the panel has exhausted its redial
attempts, a communication failure is displayed by the panel (you may have to scroll through the
messages).
The Dialer Capture module cannot sense a fault on the Tip/Ring side. However, during an alarm, if
the module cannot forward the alarm, it will trigger a fault and disable the phone line. The phone
line will be re-enabled after communication has been re-established.
If the Dialer Capture module senses a fault, it will send a Trigger signal to the control panel zone (if
wired to a zone). At this point the module will also drop the phone line voltage and will not provide a
dial tone to the control panel. During this time, the control panel will make retry attempts (8 for
residential, and more for commercial) to dial out and send a report. Until the control panel has
completed the series of retry attempts it will not be able to detect a Telco fault. To minimize the wait
time, for control panels that allow setting the Telco Fault detection time, please set it to the
minimum detection time.
For control panels that may generate erroneous Telco fault conditions based on grounding (such as
the VISTA-15P, VISTA-20P), turn off "Telco Fault" monitoring at the control panel.
If the dialer capture module receives a fault indication from the communicator, the module will
disable the phone line, causing the control panel to indicate a communication fault after a period of
time. When the dialer capture module receives a fault clear condition, the module will re-enable the
phone line.
If an AlarmNet communications device fault is detected, this will be reported to the control panel as
a com failure. If Telco fault is turned on, an AlarmNet failure will be displayed as a Telco Fault. If the
communicator fault trigger is wired to a zone, the Dialer Capture module will trigger the control
panel to alarm this zone and display a message. With some control panels, displayed alarm
messages for triggered zones may hide a "com failure" message. The com failure message can be
displayed by first clearing the zone alarm message(s).