Introduction
7/99 9782 Series Conductivity/Resistivity Analyzer/Controller - Operator’s Manual
1-15
Table 1-3 Available Combinations of Relay Assigments
Features Used Relay 1 Relay 2 Relay 3 Relay 4
Alarm 1Alarm 2Alarm 3Alarm 4
Alarm 1 and Diagnostic Alarm 2 Alarm 3 Alarm 4
Alarms Only
Alarm 1 Alarm 2 and Diagnostic Alarm 3 Alarm 4
Alarm 1 Alarm 2 and Alarm 4 Alarm 3 Alarm 2 and Alarm 4
Alarm 1 and Alarm 2 Alarm 3 and Alarm 4 Alarm 1 and Alarm 2 Alarm 3 and Alarm 4
Alarm 1
or discrete control
Alarm 2
or discrete control
Alarm 3
or discrete control
Alarm 4
or discrete control
Discrete Control
Alarm 1 and Diagnostic
Alarm 2
or discrete control
Alarm 3
or discrete control
Alarm 4
or discrete control
and Alarms
Alarm 1
or discrete control
Alarm 2 and Diagnostic
Alarm 3
or discrete control
Alarm 4
or discrete control
Alarm 1
or discrete control
Alarm 2 and Alarm 4
Alarm 3
or discrete control
Alarm 2 and Alarm 4
Alarm 1 Cell 1 Range Status Alarm 3 Alarm 4
Range Status
Alarm 1 and Alarm 2 Cell 1 Range Status Alarm 3 Alarm 4
and Alarms
Alarm 1 and Diagnostic Cell 1 Range Status Alarm 3 Alarm 4
Alarm 1 and 2 and 3 and 4 Cell 1 Range Status Alarm 1 and 2 and 3 and 4 Cell 2 Range Status
Alarm 1 and 2 and 3 and 4
and Diagnostic
Cell 1 Range Status Alarm 1 and 2 and 3 and 4
and Diagnostic
Cell 2 Range Status
Range Status,
Alarm 1
or discrete control
Cell 1 Range Status
Alarm 3
or discrete control
Alarm 4
or discrete control
Discrete Control
Alarm 1 and Alarm 2 Cell 1 Range Status
Alarm 3
or discrete control
Alarm 4
or discrete control
and Alarms
Alarm 1 and Diagnostic Cell 1 Range Status
Alarm 3
or discrete control
Alarm 4
or discrete control
AutoClean, Range
Status, and Alarms
AutoClean Cell 1 Range Status
Alarm 3
or discrete control
Alarm 4
or discrete control
With or Without
Discrete Control
AutoClean Cell 1 Range Status Alarm 2 and 3 and
Diagnostic
Alarm 4
or discrete control
AutoClean Alarm 2 Alarm 3 Alarm 4
AutoClean
AutoClean Alarm 2 and Diagnostic Alarm 3 Alarm 4
and Alarms
AutoClean Alarm 2 and 3 and 4 AutoClean Alarm 2 and 3 and 4
AutoClean Alarm 2 and 3 and 4 and
Diagnostic
AutoClean Alarm 2 and 3 and 4 and
Diagnostic
AutoClean,
AutoClean
Alarm 2
or discrete control
Alarm 3
or discrete control
Alarm 4
or discrete control
Discrete Control,
and Alarms
AutoClean Alarm 2 and Diagnostic
Alarm 3
or discrete control
Alarm 4
or discrete control