100
APT4000PH
Specifications
Protection against Protective separation of all extra-low-voltage circuits against
electrical shock mains by double insulation as per EN 61010-1
Power supply 24 (-15%) to 230 V AC/DC (+10%); approx. 5 VA, 2.5 W
AC: 45 to 65 Hz; Overvoltage category II, Class II
Nominal operating conditions
Ambient temperature -20 to +55 °C
Transport/Storage temp -20 to +70 °C
Relative humidity 10 to 95 % not condensing
Power supply 24 (-15%) to 230 V AC/DC (+10%)
Frequency for AC 45 to 65 Hz
EMC EN 61326
Emitted interference Class B (residential environment)
Class A for mains supply > 60 V DC
Immunity to
interference Industrial environment
Explosion protection
FM: NI Class I Div 2 Group A, B, C & D, T4 Ta = 55 °C; Type 2
NI Class I Zone 2 Group IIC, T4 Ta = 55°C; Type 2
Enclosure molded enclosure made of PBT (polybutylene terephtalate)
Color Bluish gray RAL 7031
Assembly • Wall mounting
• Pipe mounting: dia 40 to 60 mm, 30 to 45 mm
• Panel mounting, cutout to DIN 43 700
Sealed against panel
Dimensions H 144 mm, B 144 mm, T 105 mm
Ingress protection IP 65 / NEMA 4X
Cable glands 3 breakthroughs for cable glands M20x1.5
2 breakthroughs for NPT 1/2 “ or Rigid Metallic Conduit
Weight Approx. 1 kg
*) User-defined
1
) To IEC 746 Part 1, at nominal operating conditions
2
) ± 1 count
3
) Plus sensor error