BENDIX/KING
KAP 140
Page 4--13
Revision 2, Dec/2002
CS:15574F02.IDU
4.3.15 FLAPS INTERFACE TO THE KC 140
PIN
DESCRIPTION
P1402 -- 45 FLAPS_+
P1402 -- 46 FLAPS_--
The FLAPS input on the KC 140 interfaces to the flaps motor in the aircraft. When the flaps are
in motion, the software in the KC 140 begins running trim in the aircraft to help prevent the pitch
servo from getting behind during configuration changes. If the flaps motor voltage is greater than
9 volts, the flaps motor is determined to be running (active). The voltage on the flaps input can be
viewed on the ANALOG INPUTS diagnostic page.
DIAGNOSTIC NAME
SCALE FACTOR
Flap Voltage 1V/V (>9Vor<--9V=active)