INSTALLATION INSTRUCTIONS
34-00032-01
DB7110U Universal Heat Pump 
Defrost Controller
APPLICATION
The DB7110U Universal Heat Pump Defrost 
Controller is a heat pump defrost control used in 
single stage heat pump appliances. This product 
replaces over 260 OEM and competitive controls and 
can be easily programmed to meet the requirements 
of virtually any single stage heat pump. See Table 2, 
“Compatibility Chart.,” on page 5.
FEATURES
The DB7110U provides:
• Universal defrost control for single stage heat 
pumps
• LED display for easy setup and configuration
• Small, square footprint for easier installation
• Demand and timed defrost modes
• System status and fault indication
• Selectable reversing delay to limit noise when 
going in and out of a defrost cycle
• Fault history for easy troubleshooting
Fig. 1. DB7110U1000.
SPECIFICATIONS
Electrical Ratings
Input Voltage: 24VAC, 60Hz
Max. Input Current: 200mA
Compressor Contactor: 1A @ 24VAC
Outdoor Fan:
1/2HP motor
5A full load, 30A locked rotor, 240VAC.
Aux Heat: 1A @ 24VAC
Reversing Valve: 1A @ 24VAC
All outputs rated for 100,000 operations.
All terminals except FAN-IN and FAN-OUT are NEC 
Class 2 low voltage.
Environmental Ratings
Operating Temperature Range: -40F to 150F
Humidity Limits: less than 95% (non-condensing)
INSTALLATION AND 
CONFIGURATION
Overview
When Installing This Product… 
1. Read these instructions carefully. Failure to fol-
low instructions can damage the product or 
cause a hazardous condition. 
2. Check ratings given in these instructions and 
on the product to make sure the product is suit-
able for your application. 
3. Installer must be a trained, experienced service 
technician.
4. Use these instructions to check out the product 
operation after installation.
MENU
SETTING
SYSTEM
FAULT
M37637
DB7110U-DEFROST CONTROL