DT8016AF4 / DT8016AF5 DUAL TEC
®
Motion Sensor with Anti-Mask
FR ES SE NL IT RU UK
1
2.1 - 2.7 m
(7' - 9')
30 cm
(12")
*
* Tenir à l'écart /
Respetar obligatoriamente / Håll fritt / Vrijhouden /
Non ostacolare / Не заслонять / Keep Clear
*
2.3
m
(7' 6")
[EN]
2
2
3
1
[EN]
3
3.5 mm x 30 mm
(#6 x 1 1/4")
3.5 mm
(#6)
*
A
B
X X
* Non inclus
No Incluido
Ingår ej
Niet inbegrepen
Non Incluso
Не входит в комплект
Not Included
[EN]
A
A
B
B
B
B
A
B B
*
DT8016AF4
AM LED
EOL
KOhm
PULL
TO DISABLE
LOOK DOWN
LOOK DOWN
ON
OFF
ON
ON
W1
1 2.2 2.2 34.7 5.6 1 2.2 4.7 5.6
MW
SENSITIVITY
MAX
4
MW
SENSITIVITY
MAX
Réglage de la portée hyper
Ajuste del rango de detección
Justeringsområde för mikrovåg
Aanpassing bereik radiofrequentie
Regolazione della portata
Настройка микроволнового диапазона
Microwave Range Adjustment
*AM Enabled
AM Disabled
*
Réglage des résistances (EOL) / Ajustes de RFL /
EOL-inställningarna / EOL instellingen /
Regolazioni EOL / Настройки EOL / EOL Settings
* * *
ALARM
[RA]
TAMPER
[RT]
AM / FAULT
[RF]
EOL
KOhm
ON
ON
OFF
*
Anti-masque
Antienmascaramiento
Antimaskering
Anti-mask
Antimascheramento
Антимаскинг
Anti-mask
1
2.2 2.2
3
4.7 5.6
1
2.2 4.7 5.6
MIN
*
AM LED
AM =
* Réglage usine / valores de fábrica / Fabriksinställning / fabrieksinstellingen /
programmazione di fabbrica / Заводские настройки / factory default
[EN]
[EN]
[EN]
Remarque: Réglée au minimum, la couverture du détecteur est réduite à 5m.
Nota: Ajuste en mínimo, el rango del sensor se reduce a 5 m.
OBS! Ställ in på minsta värdet, detektorområdet minskas till 5 m.
Opmerking: Ingesteld op minimum wordt het sensor bereik gereduceerd tot 5m.
Nota: impostare al minimo, la portata del sensore è ridotta a 5m.
Примечание: При установке на минимум дальность действия датчика сокращается до 5 м.
Note: Set at mimimum, the sensor range is reduced to 5m.
[EN] = installation agréé / instalación homologado / godkänd installation /
goedgekeurde installatie / installazione omologato / хорошее место / approved installation
Question and Answer IconNeed help?

Do you have a question about the Honeywell DUAL TEC DT8016AF4 and is the answer not in the manual?

Honeywell DUAL TEC DT8016AF4 Specifications

General IconGeneral
Detection MethodPassive Infrared (PIR) and Microwave
TechnologyDual Technology
TypeMotion Detector
MountingCeiling or Wall
Power Supply9 to 15 VDC
Tamper SwitchNormally Closed (NC)

Summary

Installation and Mounting

Installation Location and Clearance

Specifies ideal sensor placement and areas to keep clear for optimal performance.

Mounting Height Recommendations

Details the recommended installation heights for effective detection.

Physical Installation Steps

Illustrates the process of physically mounting the sensor unit using hardware.

Configuration and Settings

EOL and Anti-Mask Settings

Explains DIP switch configurations for EOL resistors and Anti-Mask (AM) features.

Wiring and Connections

Details terminal connections, wire specifications, and remote LED control options.

Walk Test and Sensitivity Adjustment

Guides on performing walk tests and adjusting motion and microwave sensitivity levels.

Coverage Patterns and Approvals

Detection Coverage Patterns

Illustrates the sensor's detection range from top and side views.

Approval Listings and Certifications

Lists product certifications and compliance standards.

Related product manuals