Galaxy Programming Manual
10
Setting Features
The Galaxy control panels provide a range of features to assist the user in the setting and unsetting of the
system, minimising the possibility of error when carrying out these procedures.
Show Set Status
When Show Status is enabled (refer to option 58.6 = KEYPAD.Show Status), pressing the and # keys
simultaneously when the normal banner is displayed indicates the group set status.
F = Fault
R = Ready
S = Set
P = Part Set
L = Locked Out
= Group not assigned to keypad
NOTE: The Show Status indicates the set conditions of groups when the system is set (keypad blank) or
unset (normal banner). Show Status does not operate while engineer mode is accessed.
Pressing the and # keys again toggles the display to show the status of the groups individually. To move
between each groups, press the and A or the and B keys simultaneously.
Pressing the and # keys again returns the keypad to the banner display.
Galaxy 500, 504 and 512
The Galaxy 500, 504 and 512 have more than 8 groups; these are displayed on the keypad in blocks of eight
groups. Press and A or and B keys to display each of the group blocks.
Exit Time
Once the setting routine starts, outputs programmed as Entry/Exit Horn emit a continuous tone. The keypad
used to set the system indicates the time, in seconds, remaining before the system sets.
Exit Time Reset
If any zones are open when setting starts or are opened during the setting routine, the sounder begins to pulse
rapidly; zones types other than Final, Exit, Entry or Push-Set (and Secure Final or Part Final when acting
as a Final), indicate on the setting keypad the number of zones open. The A or B keys can be used to view
the open zone types and addresses. Closing the zones resets and restarts the exit time.
Setting Features
08:58 TUE 22 NOV
A1U Group A1
Group A1 is unset
STATUS 12345678
Groups RRSRLPFP
Group Block