Galaxy Programming Manual
21
Option 25 – Access Doors
NOTE: If the MAX mode has not been enabled (refer to option 63.2 = OPTIONS.MAX) the message No
Entries is displayed on entering this option.
Accessing this option when the MAX mode is enabled and there are MAX modules connected to the system
displays the address and descriptor details of the first MAX module on the system. Press the A and B keys to
view details of the other MAX modules on the system.
If there are no MAX modules attached to the system the message None Detected is displayed.
The MAX/MicroMAX/MAX
3
log size mirrors the panel event log size. For example, the Galaxy 60 has a
MAX/MicroMAX/MAX
3
log size of 300 events, and the Galaxy 500 has a MAX/MicroMAX/MAX
3
log size
of 500 events. Full details of the MAX/MicroMAX/MAX
3
log sizes for each panel type are given in Galaxy
Installation Manual, Appendix B, Panel Comparisons (part number II1-0030).
MAX/MicroMAX/MAX
3
events are transmitted using Contact ID, SIA and Alarm Monitoring formats.
MAX/MicroMAX/MAX
3
events transmitted are listed in the table that follows:
Table 3. Max/MicroMAX/MAX
3
Events
Access Log Print and Store Option
The Access Doors (MAX/MicroMAX Log) is printed on-line and stored in the event memory.
The Access Door Log print displays in the format of the Event Log and allows information to be accessed.
The format is as follows:
HH:MM_XXXXXXXXXX_USR_NNN_UUUUUU_MYY_—_ (39 character display)
HH:MM = time in hour:minutes (5 characters). The date will be printed only at the beginning of every day,
that is midnight.
XXXXXXXXXX = access message (10 character) Valid, Invalid Vard, Reject Card
USR = User (3 characters)
NNN = User number to which MAX card is assigned (3 characters)
UUUUUU = User descriptor (6 characters)
M = MAX reader address (1 character)
YY = MAX physical address-M10, M24 etc (3 characters)
- (dash) = unused character slot
__ (underscore) = this represents a space and is not printed or displayed in the access log.
For example: A valid card read at MicroMAX/MAX
3
30 from the card held by user 020, name Albert, at
13:48 would be:-
13:48 Valid USR 020 Albert M30 –
25 - Access Doors
tnevEnoitpircseDedoCAIS
DIC
edoC
reggirToNdoMDIresU
sseccA
detnarG
dnadetneserpdracdilaV
detadilav
GD124SGATXAMseYseY
draCdilavnI
tonsahdetneserpdraC
otnodemmargorpneeb
metsys
DD224SGATXAMseYoN
draC
detcejeR
tub,detneserpdracdilaV
nosaeremosrofdetcejer
KD224SGATXAMseYseY