Galaxy Programming Manual
68
8 = Group (Galaxy 18, 60, 128, 500, 504 & 512)
NOTE: The Groups attribute is only available if groups have been enabled on the system (refer to option 63
= OPTIONS).
The Group attribute allows the zone to be assigned to a single group on the system. All zones default to
Group A1.
On selecting the Group attribute, the group that the zone is currently assigned to is displayed. All zones
default to group A1. Press the number of the group that the zone is to be reassigned to and press the ent key.
Galaxy 500, 504 & 512
The Galaxy 500, 504 and 512 panels have 16, 32 and 32 groups respectively; these are displayed on the
keypad in blocks of eight groups, sub-divided into A, B, C and D:
Use the A or B key to select the required group (A1–D8). When the end of a block is reached, the next
block of eight groups is displayed; use keys 1–8 to assign the relevant group in the current block to the zone;
press the ent key to accept the selection.
Star (
) Group Function
Certain zone functions have an additional Group attribute feature that allows the other groups to be affected
by their operation. This feature is assigned by pressing the key when allocating the group to the zone.
On pressing the key the display indicates the group currently assigned to the zone and prompts for other
groups to be added, for example 1 1 – – – – – – –, pressing 4 and 7 assigns 1 1 – – 4 – – 7 –.
Final, Secure Final, Part Final Keyswitch and Push Set Zones
If the star group feature is assigned a zone programmed as Final, Secure Final, Part Final or Push Set,
then closing the zone when setting multiple groups terminates the setting procedure for all groups assigned to
the zone.
Refer to the zone functions for further information on the operation of these zone functions.
Exit Zones
The star group feature can be assigned to a zone programmed as Exit. This allows an Exit zone to be
activated in a group which is not currently being unset without activating an Intruder alarm condition.
Refer to the zone functions for further information on the operation of this zone function.
System Alarms
The Galaxy panels have tamper and alarm monitoring circuits which are not programmable. These circuits
maintain the integrity of the system and all correspond to Group A1.
52 - Program Zones (cont’d)
enoZmralAnoitpircseD
1000TTABUCwolyrettabtinulortnoC
2000CAUCliafCAtinulortnoC
3000REPMATDILrepmatdiltinulortnoC
4000REPMATXUAnruterrepmattinulortnoC
Table 13. Control Panel Alarms