Granit XP User Guide 109
9999 code length that must match for PDF417, 9999 = all
lengths
4D start character match for PDF417, 4Dh = “M”
FF termination string for third code
SEQSEP99 separator for each sequence, 99 = all symbologies
3C left bracket (<)
3E right bracket (>)
SEQSUF99 separator for suffixes, 99 = all symbologies
0D carriage return
0A line feed
And you would add >PARTIAL< as the prefix to note the partial sequence:
SEQTTS1 transmit partial sequence
SEQISU99 add partial sequence prefix, 99 = all symbologies
3E right bracket (>)
50 P
41 A
52 R
54 T
49 I
41 A
4C L
3C left bracket (<)
The whole command line would look like this:
SEQBLK62999943FF6A999954FF7299994DFFSEQSEP993C3ESEQSUF990D0
ASEQTTS1SEQISU993E5041525449414C3C
The data is output as:
>PARTIAL<
<TSTMSGCODE128>
<MSGPDF417>