EasyManua.ls Logo

Honeywell KHF 1050 - 5.D. Strapping Options; 5.D.(1) KRX 1053 Receiver;Exciter Strapping Options

Honeywell KHF 1050
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
N
KHF 1050 SYSTEM INSTALLATION MANUAL
Page 2033
Revison 2 23-10-09 Apr/2006
5.D. Strapping Options
5.D.(1) KRX 1053 Receiver/Exciter Strapping Options
NOTE: Asserted = GND, Not Asserted = OPEN
Refer to “Figure 2029 - KHF 1050 HF System Interconnect” for KRX 1053
strapping options.
5.D.(1)(a) Power ON/OFF Control - (J10531-23) PWR CONT
An external controller turns on the KRX 1053 Receiver/Exciter by asserting
(grounding) the POWER ON/OFF CONTROL discrete input. In an
installation in which LRU power is to be controlled by a radio master switch
or relay, this input may be permanently strapped to ground. Also see
Paragraph “4.A.(1) System Power UP” .
This input is continuously read.
5.D.(1)(b) Controller Select - (J10531-57) CONT SEL
When set up to operate in the continuous TUNING MODE, the
CONTROLLER SELECT discrete determines which HF controller input is
active.
The KRX 1053 Receiver/Exciter accepts tuning and control data from the
HF CONTROLLER INPUT #1 when the CONTROLLER SELECT and
TUNING MODE discrete inputs are not asserted.
The KRX 1053 Receiver/Exciter accepts tuning and control data from the
HF CONTROLLER INPUT #2 when the CONTROLLER SELECT discrete
input is asserted and the TUNING MODE discrete input is not asserted.
This input is continuously read.
5.D.(1)(c) Burst/Continuous Tuning Mode - (J10531-15) TUNE MODE
When the BURST/CONTINUOUS TUNING MODE discrete input is not
asserted, the KRX 1053 Receiver/Exciter operates with continuous ARINC
429 tuning and mode control data and the CONTROLLER SELECT discrete
input determines the active controller input.
NOTE: Continuous mode not currently available.