EasyManuals Logo

Honeywell KHF 1050 User Manual

Honeywell KHF 1050
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
N
KHF 1050 SYSTEM INSTALLATION MANUAL
Page 2001
Revison 2 23-10-09 Apr/2006
INSTALLATION AND MAINTENANCE
1. General Coverage
This section provides service personnel with installation and maintenance information
pertaining to the following KHF 1050 HF Communication System components:
The conditions and test required for the TSO and MOPS approval of this article are
minimum performance standards. It is the responsibility of those installing this article
either on or with a specified type or class of aircraft to determine that the aircraft
installation conditions are within the TSO and MOPS standards. These articles must
have separate approval for installation in an aircraft. Any features in this equipment
outside the requirements of this applicable TSO and MOPS must be evaluated and
approved as part of the installation approval. The article may be installed only if
performed under 14 CFR Part 43 or the applicable airworthiness requirements.
KAC 1052 Antenna Coupler
KPA 1052 Power Amplifier
KRX 1053 Receiver/Exciter
NOTE: For installation and maintenance information on the MC-850 MCDU refer to
the MC-850 installation documentation pertinent to each specific application.
For installation and maintenance information on the RM-855 RMU refer to the
Primus
®
II SRZ-85X Integrated Radio System Operation and Installation
Manual P/N A15-3800-001.
1.A Instructions for Continued Airworthiness
The instructions for continued airworthiness given in the TC or STC approvals for
this product supplements or supersedes the instructions for continued
airworthiness in this manual.
Most Honeywell products are designed and manufactured to allow “on condition
maintenance”. On condition maintenance is described as follows; There are no
periodic service requirements necessary to maintain continued airworthiness. No
maintenance is required until the equipment does not properly perform the
intended function. When service is required, a complete performance test should
be accomplished following any repair action. Consult the appropriate unit
Maintenance/Overhaul Manual for complete performance test information.
The only exception to the “on condition maintenance” statement for the KHF 1050
System is the KAC 1052 pressurization check described in Paragraph 10.A.(2)
KAC 1052 Pressurization.

Table of Contents

Other manuals for Honeywell KHF 1050