- 4 -
Data Field Display Function& Programming Options [ ] = Programmed Table 1 Default Values
30
3030
30
DST
DST DST
DST
WEEK
WEEK WEEK
WEEK
STR/END
STR/ENDSTR/END
STR/END
Daylight Saving Time Start/End Weekend
[2,1]
Start End
0=disable; 1=first; 2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last
ZONE SOUNDS AND TIMING (✻31–
✻39) † Entering a number other than the one specified may give unpredictable results.
31
3131
31
SINGLE
SINGLE SINGLE
SINGLE
ALARM
ALARM ALARM
ALARM
SND
SNDSND
SND
Single Alarm Sounding/Zone UL installations = 0
† [0]
0 = Alarm Sounding Per Zone will be the same as the Swinger Shutdown” set in field *92;
1 = yes, limit once per arming period (also applies to long range radio output if “0” is
selected in ✻91 field)
32
3232
32
FIRE
FIRE FIRE
FIRE
SND
SNDSND
SND
TIMEOUT
TIMEOUT TIMEOUT
TIMEOUT
Sounder Timeout
† [0]
0=timeout; 1=no timeout
33
3333
33
ALRM
ALRM ALRM
ALRM
SND
SND SND
SND
TIMEOUT
TIMEOUTTIMEOUT
TIMEOUT
Alarm Bell Timeout UL installations = 1 (4 min) minimum
† [1]
0 = none; 1=4 min; 2=8 min; 3=12 min; 4 = 16 min
34
3434
34
EXIT
EXIT EXIT
EXIT
DELAY
DELAYDELAY
DELAY
TIME
TIME TIME
TIME
Exit Delay UL installations = 60 seconds max.
| † [70]
00-99 = exit delay time (in seconds)
35
3535
35
ENTRY
ENTRY ENTRY
ENTRY
DELAY
DELAYDELAY
DELAY
1
1 1
1
Entry Delay 1 (zone type 01) UL installations = 45 seconds max.
| † [30]
00-99 = entry delay time (in seconds)
36
3636
36
ENTRY
ENTRY ENTRY
ENTRY
DELAY
DELAY DELAY
DELAY
2
22
2
Entry Delay 2 (zone type 02) UL installations = 45 seconds max.
| † [60]
00-99 = entry delay 2 time (in seconds)
37
3737
37
EX
EXEX
EXI
II
IT
T T
T
SND/QK
SND/QK SND/QK
SND/QK
EXIT
EXITEXIT
EXIT
Audible Exit Warning / Quick Exit
† [1, 1]
Exit Warn Quick Exit
0 = no; 1 = yes
38
3838
38
CON
CONCON
CONF
FF
F
ARM
ARMARM
ARM
ING
INGING
ING
DING
DINGDING
DING
Confirmation of Arming Ding
Note: Confirmation ding only sounds when LYNX is Armed Away or disarmed after being Armed
Away. If LYNX is armed by RF button (key fob), a confirmation ding occurs immediately after arming
regardless of field
✻38 settings. If LYNX is disarmed by RF button (key fob), additional disarming
confirmation ding occurs immediately after disarming and is longer than arming confirmation ding.
† [0]
0 = no arming confirmation ding after arming system by APX32EN keypad or RF keypad; 1 = arming
confirmation ding after arming system by APX32EN keypad or RF keypad;
2 = arming confirmation
ding after arming from RF keypad only
39
3939
39
PWR
PWR PWR
PWR
UP
UP UP
UP
PRV
PRV PRV
PRV
STATE
STATESTATE
STATE
Power Up In Previous State
† [1]
0 = no; 1 = yes; UL installations = 1
DIALER PROGRAMMING (✻40– ✻53) In fields ✻40, ✻41, ✻42, enter up to the number of digits shown.
Enter 0–9; #+11 for '
✻'; #+12 for '#'; #+13 for a pause.
40
4040
40
PABX
PABX PABX
PABX
ACCESS
ACCESS ACCESS
ACCESS
CODE
CODECODE
CODE
PABX Access Code
Enter 6 digits. If fewer than 6 digits are entered, pressing ✻ advances to the next field. To
clear entries from field, press ✻40✻
† Entering a number other than the one specified may give unpredictable results.