- 9 -
Data Field Display Function& Programming Options [ ] = Programmed Table 1 Default Values
89
8989
89
EVNT
EVNT EVNT
EVNT
LOG
LOG LOG
LOG
80%
80% 80%
80%
REP
REPREP
REP
Event Log 80% Full Report Code
|
[0,0]
90
9090
90
EVNT
EVNT EVNT
EVNT
LOG
LOG LOG
LOG
OPTIONS
OPTIONSOPTIONS
OPTIONS
Event Logging Note: System messages are logged when
any non-zero selection is made.
[3]
0 = None; 1 = Alarm/Alarm Restore; 2 = Trouble/Trouble Restore; 4 = Bypass/Bypass
Restore; 8 = Open/Close.
Example: To select “Alarm/Alarm Restore”, and “Open/Close”, enter 9 (1 + 8); To select
all, enter #15.
91
9191
91
AAV/REM
AAV/REMAAV/REM
AAV/REM
PHN
PHN PHN
PHN
CTRL
CTRLCTRL
CTRL
Alarm Audio Verification (AAV)/Remote Phone Control
[2]
0 = None
1 = AAV and remote phone control
2 = remote phone control only
4 = AAV only
Notes: (1) In order to activate the Remote Phone Control feature and defeat an answering machine,
ensure that the correct ring detection count (“15”) has been programmed in field 95.
(2) Remote phone session will be terminated if a report must be sent.
(3) Alarm Audio Verification will only function when Contact ID® is selected. AAV cannot be
used for UL installations.
(4) If an alarm will be reported to primary and secondary phone numbers, AAV can only
function via the secondary number.
(5) If an alarm will be reported to a follow me phone number (10-12 in field 49) AAV cannot
be used.
(6) If AAV is selected and LRR/IP communications device is enabled, you must enter "0"
(primary dialer preferred channel) as the second entry in Field 77.
92
9292
92
# REPS
REPS REPS
REPS
ARMED
ARMED ARMED
ARMED
PER
PERPER
PER
Number of Reports In Armed Period
[0]
0 = 10 Alarm/Alarm Restore Reports;1 = Unlimited (UL installations = 0)
DOWNLOAD INFORMATION (93–95)
93
9393
93
FLEXBLE
FLEXBLE FLEXBLE
FLEXBLE
CALLBACK
CALLBACKCALLBACK
CALLBACK
Flexible Callback
[0]
0 = No flexible callback; 1 = Last digit flexible;
2 = Last 2 digits flexible; 3 = Last 3 digits flexible
94
9494
94
DOWNLOAD
DOWNLOAD DOWNLOAD
DOWNLOAD
PHONE
PHONE PHONE
PHONE
#
Download Phone Number
Note: In UL installations, downloading may only be performed if a technician is at the site.
Enter up to 20 digits, 0–9; #+11 for ''; #+12 for '#'; #+13 for a pause. Do not fill unused
spaces. If fewer than 20 digits entered, pressing advances to the next field. To clear
entries from field, press 94.
95
9595
95
RING
RING RING
RING
DET
DET DET
DET
COUNT
COUNTCOUNT
COUNT
Ring Detection Count for Downloading/Remote Phone Control Mode
[15]
0 = Disable Station Initiated Download
1–14 = number of rings
(1–9, [#]+10 =10, [#] +11 =11, [#] +12 =12, [#] +13 =13, [#] +14 =14);
15 = answering machine defeat ([#] +15 =15)

Other manuals for Honeywell Lynx Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Lynx Plus and is the answer not in the manual?

Honeywell Lynx Plus Specifications

General IconGeneral
ModelLynx Plus
Battery BackupYes
Voice PromptsYes
InstallationDIY or professional
User Codes8
DisplayLCD
KeypadBuilt-in
SirenBuilt-in
CompatibilityHoneywell 5800 series wireless devices
Panel TypeSelf-Contained Wireless Security System
Warranty2 years

Related product manuals